Rinnai V3237FFU ユーザーズマニュアル

ページ / 52
45
Rinnai  Corporation
V3237  Models
ELECTRICAL  CONNECTION  NOTES  (OUTDOOR  UNIT)
1) The  Rinnai  Water  Heater  requires 
120VAC/60  Hz,  power  from  a  properly 
grounded  circuit. 
2) An  on/off  switch  may  be  required  and 
installed  for  the  incoming  120VAC  power. 
3)  Wire  the  Rinnai  Water  Heater  exactly  as 
shown  in  the  wiring  diagram  on  the  inside 
of  the  cover  panel.   The  black  wire  is  the 
hot  leg  wire;  the  white  wire  is  the  neutral 
wire.   
4) A  green  screw  is  provided  in  the  junction 
box  for  the  grounding  connection.
Your disconnect switch should be a type that 
is suitable for outdoor use. Check National 
Electrical Codes for proper type switch to use in 
your area. 
The Rinnai Water Heater must be electrically grounded in accordance with local
codes or in the absence of local codes with the most recent edition of the National
Electrical Code, ANSI/NFPA 70. In Canada, all electrical wiring to the Rinnai Water
Heater should be in accordance with local codes and the Canadian Electrical Code,
CSA C22.1 Part 1. Do not rely on the gas or water piping to ground the metal parts
of the water heater.
Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper operation. Verify proper operation after servicing.
120VAC CONNECTION WIRES
(Black-Hot/White-Neutral)
DISCONNECT
SWITCH
GROUND
TERMINAL