Empire Products DVC-35T-1 ユーザーズマニュアル

ページ / 24
Page 14
 
13119-6-0107
The correct pilot flame (Figure 12) will be blue, extending past 
the thermocouple. The flame will surround the thermocouple just 
below the tip.
Natural gas pilots require adjusting when the inlet gas pressure is 
above 5” w.c. (1.245kPa). Remove the pilot cover screw on the 
control valve (Figure 3), and turn the adjustment screw clockwise 
to reduce flame. Replace pilot cover screw to eliminate gas leaking 
at that control valve opening.
LP gas (propane) will not require adjustment.
After use, cleaning may be required for the proper flame.
IP-Model Pilot
This  heater  is  using  a  Honeywell  “Smart  Valve”  system  for 
intermittent pilot ignition.
On a call for heat by the thermostat this control turns on a 24 volt 
mini hot surface ignitor which lights a pilot that in turn lights the 
main burner. The gas valve used in this system is a step opening 
which opens at a lower pressure for ignition and then steps to a 
full inlet pressure of 4” pressure on Natural gas and 10” pressure 
on LP gas.
Pilot Flame Adjustment
The pilot flame should envelop 3/8 to 1/2 inch (10 to 13mm) of the 
tip of the flame rod. See Figure 12.
To adjust:
1. Remove the pilot adjustment cover screw.
2. Turn the inner adjustment screw clockwise 
to decrease 
or counterclockwise 
 to increase pilot flame. Pilot ad-
justment is shipped at full flow rate. Turn the inner adjustment 
screw clockwise
 if the inlet pressure is too high.
3. Replace the cover screw after the adjustment to prevent gas 
leakage.
SPARK�
ELECTRODE
THERMOCOUPLE
PILOT
BURNER
STANDING PILOT
PILOT LOCATION END VIEW
PILOT SHIELD
THERMOCOUPLE
SPARK�
ELECTRODE
STANDING PILOT SHOWN
BURNER
PILOT
HOT SURFACE�
IGNITOR
FLAME�
ROD
GROUND�
ELECTRODE
3/8" TO 1/2"�
PILOT FLAME
IP-MODEL PILOT
Figure 12
PILOT FLAME CHARACTERISTICS