Empire Products DV-25T-1 ユーザーズマニュアル

ページ / 20
13117-9-0907
Page 6
Introduction
Always  consult  your  local  Building  Department  regarding 
regulations, codes or ordinances which apply to the installation of 
a direct vent wall furnace.
Instructions to Installer
1.  Installer  must  leave  instruction  manual  with  owner  after 
installation.
2.  Installer  must  have  owner  fill  out  and  mail  warranty  card 
supplied with furnace.
3.  Installer should show owner how to start and operate furnace 
and thermostat.
Warning:
Any change to this furnace or its control can be dangerous.  
This is a heating appliance and any panel, door or guard 
removed for servicing an appliance must be replaced prior 
to operating the appliance.
General Information
This furnace is design certified in accordance with American National 
Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian 
Standard Association, as a Gravity Direct Vent Wall Furnace to be 
installed on an outside wall according to these instructions.
Any alteration of the original design, installed other than as 
shown in these instructions or use with a type of gas not shown on 
the rating plate is the responsibility of the person and company 
making the change.
Important
All correspondence should refer to complete Model No., Serial 
No. and type of gas.
Notice:  During initial firing of this unit, its paint will bake out  and 
smoke will occur.  To prevent triggering of smoke alarms, ventilate 
the room in which the unit is installed.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed 
so that all burners and burner ignition devices are located not less 
than 18" (457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject 
to physical damage by a moving vehicle.  
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment 
or  accessories  and  repair  and  servicing  of  equipment  shall  be 
performed only by a  qualified agency.  The term "qualified agency" 
means any individual, firm, corporation or company which either in 
person or through a representative is engaged in and is responsible 
for  (a)  the  installation  or  replacement  of  gas  piping  or  (b)  the 
connection, installation, repair or servicing of equipment, who is 
experienced in such work, familiar with all precautions required 
and has complied with all the requirements of the authority having 
jurisdiction.
State  of  Massachusetts:  The  installation  must  be  made  by 
a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.
The installation must conform with local codes or, in the absence of 
local codes, with the National Fuel Gas Code ANSI  Z223.1/NFPA 
54* Natural Gas and Propane Installation Code, CSA B149.1.
*Available from the American National Standards Institute, Inc., 11 West 42nd St., 
New York, NY 10036.
High Altitudes
For  altitudes/elevations  above  2,000  feet  (610m),  input  ratings 
should be reduced at the rate of 4 percent for each 1,000 (305m) 
feet above sea level.  Canadian High Altitudes for locations having 
an elevation above mean sea level between 2,000 feet (610m) and 
4,500 feet (1370m), the manifold pressure is to be decreased from 
4.0" w.c. (.996kPa) to 3.2" w.c. (.796kPa) for Natural Gas and from 
10.0" w.c. (2.49kPa) to 8.0" w.c. (1.992kPa) for Propane Gas.
Model
DV-25T
DV-35T
Input BTU/HR (KW/H)
25,000 (7.3)
35,000 (10.3)
Height
27 3/4" (705mm)
27 3/4" (705mm)
Width
37" (940mm)
37" (940mm)
Depth
11 1/2" (292mm)
11 1/2" (292mm)
Gas Inlet (Pipe)
1/2" (13mm)
1/2" (13mm)
Accessories
Blower Package
DRB-1
DRB-1
*Vinyl Siding Vent Kit
DV-822
DV-822
Vent Kit (8" to 12" wall depth)
DV4T-812-1
DV4T-812-1
Vent Kit (12" to 19" wall depth)
DV4T-1219-1
DV4T-1219-1
* Vinyl siding vent kit, DV-822 adds 3" to wall depth.  You must include the three (3) additional inches for TOTAL wall depth when 
ordering a vent kit.
INTRODUCTION
SPECIFICATIONS