Thermo Products CMA2-75N ユーザーズマニュアル

ページ / 55
All installations and services must be performed by qualified service personnel. 
INSTALLATION PARTS PACKAGE 
 
 
 
CMA*-50
CMA*-75
S00S4179
S00S4114
PART #
QTY
PART #
QTY
J-box cover
350020
1
350020
1
wire nut
300132
2
300132
2
3" stainless steel hose clamp
300276
4
300276
4
2-3/8" radiator hose
410017
2
410017
2
CPVC adapter
320833
1
320833
1
LP conversion kit
AOPS7677
1
AOPS7678
1
                         PARTS PKG#     
DESCRIPTION
 
 
 
 
 
 
 
III.  GENERAL INSTRUCTIONS AND CLEARANCES – READ BEFORE START OF  
INSTALLATION 
 
1.  The BTU output capacity of the furnace proposed for installation should be based 
on a heat loss calculation made according to the manuals provided by the Air 
Conditioning Contractors of America (ACCA) or the American Society of Heating, 
Refrigeration and Air Conditioning Engineers, Inc. (ASHRAE). 
 
2.  This furnace is equipped with orifices sized for operation with natural gas.  For 
conversion to Propane Gas see instruction MG-799 in Gas Conversion Kit 
AOPS7678. 
 
3.  These Category Type IV furnaces are shipped completely assembled and wired 
(internally). See the Dealer Receiving and Freight Claim Procedure Section of the 
price guide for parts shortage or damage. The furnace and duct system must be 
adjusted to obtain a temperature rise of 40°F to 70°F through the furnace after 
installation. (See rating label located on separator panel inside the furnace 
vestibule). The installation must conform with local codes, or in the absence of local 
codes, with the National Fuel Gas Codes (ANSI Z223.1 or latest edition) and with 
these instructions. 
 
: This furnace is not to be used for temporary heating of buildings or 
structures under construction. 
 
Many of the chemicals used during construction, when burned, form acid bearing 
condensate that can substantially reduce the life of the heat exchanger. 
 
4.  It is recommended that a commercially available CO alarm be installed in 
conjunction with any fossil fuel burning appliance.  The CO alarm shall be installed 
according to the alarm manufacturer’s installation instructions and be listed in 
 
7