PRODUCT DATA
68-0105-2
® U.S. Registered Trademark
Copyright © 2002 Honeywell •  All Rights Reserved 
R8182D,E,F,H,J Combination
 Protectorelay™ and Hydronic
Heating Controls
GENERAL
The R8182 is a combination Protectorelay™ intermittent 
ignition oil burner primary and immersion type Aquastat® 
controller for oil-fired, hydronic heating systems.
FEATURES
• Depending on model, these single unit devices provide 
combinations of high limit, low limit, and circulator 
control.
• All models use a 24V thermostat and C554A Cadmium 
Sulfide Flame Detector.
• R8182D,E,H and J have auxiliary terminals ZC and ZR 
for circulator zone control. Additional zones require a 
separate 24V thermostat and R845 Relay.
• All models have capability for zone control with zone 
valves. Each additional zone requires a separate 24V 
thermostat and a V8043 or V8044 Zone Valve.
• Ideal for packaged boiler systems requiring compact, 
multipurpose controls.
• R8182D,E,F mode
• R8182H,J models mount on a 4 x 4 inch junction box, 
and have a 5 ft (1.5m) armored capillary for remote 
sensor location.
• Aquastat® Controller section is field replaceable.
• Oil burner circuit includes an improved safety shutoff 
in the event the burner fails to start.
• Flame failure during the running cycle results in a 
45 second attempt to restart. If unsuccessful, safety 
shutoff occurs, requiring manual reset before burner 
can be restarted.