Sterling SDA 1000-5100 ユーザーズマニュアル

ページ / 61
Large Dehumidifying Dryers  
Functional Description 
15 
2-3   Controller Description 
The AP0 control package uses a relay logic controller to control the operation of the dryer. 
See below for descriptions of each screen. 
Figure 2: Controller Screen Descriptions  
 
Regen Set Screen. Displays heating and cooling times for regeneration.  Also used to 
change times if necessary. 
Material Miser OFF Screen. Used to enable material miser valve. 
Material Miser ON Screen.  Used to disable material miser valve. 
Closed Loop Regen OFF Screen:  Used to enable closed loop cooling on 
regeneration. 
Closed Loop Regen ON Screen:  Used to disable closed loop cooling on 
regeneration. 
I/O Status Screen.  Used to view the status of inputs and outputs for the dryer. 
Alarm Screen.  Shows which alarm the dryer gets.