Sterling 350-2100 CFM ユーザーズマニュアル

ページ / 58
350-2100 cfm Dryers 
Chapter 6: Maintenance 
43 of 58 
 
 
Display 
Characters 
Sensor Type 
Switch 
Position 
Temp 
Range 
 
 
  
°C 
°F 
 
 
 
Thermocouple Type R 
0 - 1,700 
0 - 3,000 
 
 
 
Thermocouple Type S 
0 - 1,700 
0 - 3,000 
  
 
 
Thermocouple Type K 
-200  to  
1,300 
-300 to 
2,300 
 
 
 
Thermocouple Type J 
-100 to 
900 
-100 to  
1,600 
 
 
 
Thermocouple Type T 
-200 to 
400 
-300 to 
700 
 
 
 
Thermocouple Type E 
0 to 600 
0 to 1,100
 
 
 
Platinum RTD (JIS 
1981) 
6 -99.9 
to 
450.0 
-99.9 to 
800.0 
 
 
 
Platinum RTD (DIN) 
-99.9 to 
450.0 
-99.9 to 
800.0 
 
Not Used 
 
 
 
Not Used 
 
 
 
9.  Set both transmission output selector DIP switches OFF. They are marked SW207 (TRANSFER) 
and are on the right circuit board on controls equipped with optional communications. See the 
Communications Manual [part number A0535959]. 
1
2
3
4
5
6
ON
 
10.  The function selector DIP switch [SW201 (FUNCTION)] selects 6 control modes. It is on the right 
circuit board. Put this switch in the set-up configuration at right while inputting the initial control 
parameters. 
 
SW201 Set-up Configuration 
1 OFF 
Control Mode  
2 OFF 
Normal/Reverse Output 
3 OFF 
Input Shift 
4 OFF 
Temperature Sensor 
Standard  
5 ON 
Scale Indication 
6 ON  
PID Constant Indication