Sterling SDA 150-380 ユーザーズマニュアル

ページ / 52
 
 
Cabinet Series Dehumidifying Dryer 
 
34 
twenty minutes to cool down the process. The regeneration cycle of the off-line bed completes the 
cycle before the dryer shuts down completely. 
4.  To override the sequence shutdown turn the system ON/OFF switch to OFF
5.  To completely shut off the unit after sequence shutdown has completed, turn the system ON/OFF 
switch to OFF
6.  If needed, empty the drying hopper. 
7.  For maintenance or a long term shutdown, open (de-energize) the electrical disconnects at the 
dryer and at the power drop.