Sterling SDA 150-380 ユーザーズマニュアル

ページ / 52
 
 
Cabinet Series Dehumidifying Dryer 
 
44 
Initialize 
Setup 
6UE1 Control Output 1 
Assignment 
Heat/Cool/Alarm 1/Alarm 2/Alarm 3/ 
LBA 
Heat Default 
Setup 
6UE2 Control Output 2 
Assignment  
Heat/Cool/Alarm 1/Alarm 2/Alarm 3/ 
LBA 
AL-1 Default 
Setup 
Sub 1 Auxiliary Output 
1 Assignment  
Alarm 1/Alm 2/Alm 3/LBA/S.ERR/E333 
AL-1 
Default 
Setup  ALE1 Alarm 1 Type 
0 to 11  
Default 
Setup 
AL1n Alarm 1 open in 
alarm  
NO/NC NO 
Default 
 
Setup  ALE2 Alarm 2 Type 
0 to 11 
Default 
Setup 
AL2n Alarm 2 open in 
alarm 
NO/NC NO 
Default 
Setup  ALE3 Alarm Type  
0 to 11  
Default 
Setup 
AL3n Alarm 3 open in 
alarm 
NO/NC NO 
Default 
Setup 
6rEu Direct/Reverse 
Operation   
OR-R/OR-D OR-R 
Default 
 
Mode Parameter 
Setting 
range 
Default 
Factory 
setting 
Expansion 
SL-H Set Point Upper 
Limit 
SP Lower Limit +1 to Scaling Upper 
Limit  
1300 400.0 
Expansion 
SL-L Set Point Lower 
Limit 
Scaling Upper Limit to SP Lower Limit  -200 
Expansion CnEL PID/ON/OFF 
PID/ON/OFF 
PID 
Default 
Expansion 
SE ST Adaptive Tuning 
(Fuzzy) 
OFF/ON OFF 
Default 
Expansion  SE-b ST Stable Range  0.1 to 999.9 
°C/F 
15 Default 
Expansion  ALFA 
α 
0.01 to 1.00 
0.65 
Default 
Expansion 
AE-G AT Calculated 
Gain  
0.1 to  10.0 
1.0 
Default 
Expansion 
rESE Standby 
Sequence Reset 
Setting Method  
0/1 0 
Default 
 
Expansion 
rEE Automatic Return 
of Display Mode 
0 to 99 SEC 
Default 
Expansion  AE-H AT Hysteresis 
0.1 to 9.9% FS 
0.2 
Default 
Expansion 
LbAb LBA Detection  
Width 
0.0 to 999.9% FS 
0.2 
Default 
 
 
 
Option Boards 
 