Ultra-Aire 100V Installer’s & Owner’s Manual
Ultra-Aire 100V Installer’s & Owner’s Manual
FOR HVAC INSTALLER AND HOMEOWNER
8.  Verify additional optional control operations such as fan interlock 
or lockout.
9. Proceed to operation/setting section.
 FOR INSTALLER & HOMEOWNER:
5.3 Operation
5.3A Display
•   When there is power to the control, the control display will 
show the time, day, humidity, and temperature. 
•   When the control is turned on, the setpoint, fan status, 
auto/hold mode, and fresh air vent status is displayed.  
•  When a key is pressed the display will light.
•   The 
“TIME”
 and 
“DAY”
 is displayed at the top of  
the screen.
•  RH and Temperature are displayed in real time.
•   An “
O” before the set point, vent, or fan indicates the unit 
is operating the device.  
•   A flashing “
O” before the set point, vent, or fan indicates 
the unit is in a delay prior to operating the device.
Note: Delay is an intentional factory installed time delay 
cycle that is meant to prevent short cycles, extending the 
life of the Ultra-Aire. If a delay is encountered, 
WAIT 10 
MINUTES BEFORE EXPECTING NORMAL OPERATION.  
5.3B Setting
During the set-up process, if you make a mistake, simply 
continue. You can always go back to adjust the settings.  If 
you leave the control alone and don’t touch any buttons for 
10 seconds, the control will remember any changes made 
and return to “home.”
5.3C On/Off Setting
Press the 
“ON/OFF” button to turn the system on or off. 
When the system is on, the setpoint, fan status, auto/hold 
mode, and fresh air vent status is displayed. In the off 
mode, the control will show the time, day, humidity, and 
temperature. When the unit is shipped, it is in manual mode.     
5.3D Setting Clock Time
1.   Press and hold the 
“CLOCK”
 button.  The hour display  
will flash. Release the button.
2.  Use the 
“UP/DOWN RH” 
buttons to change the value. 
3.   Press the 
“CLOCK”
 button again and the minute display 
will flash. Use the RH buttons to change the value.
4.   Press the 
“CLOCK”
 button again and the
 “
AM/PM”
 display 
will flash. Use the RH buttons to toggle the value.
5.   Press the 
“CLOCK” button again and the day display will 
flash. Use the 
“RH” buttons to change the value.
If the 
“CLOCK” button is pressed again or no button is 
pressed for 5 seconds, the display will automatically return to 
“home.”   
5.3E Setting Relative Humidity Setpoint 
The relative humidity setpoint (the average RH that is 
maintained) operates the dehumidifier function of the Ultra-
Aire. It has no effect on any other function of the unit. The 
control senses the ambient relative humidity of the space in 
which it is located.