Aprilaire 5000 ユーザーズマニュアル

ページ / 8
An Aprilaire
®
Automatic Humidifier can be mounted upstream from the air cleaner. 
CAUTION: Do not install an atomizing humidifier upstream from the air cleaner.
INSTALLATION
Important
Airflow
Upflow "Highboy" - Closet Installation
(Bottom Return)
Airflow
Horizontal Installation
Airflow
Upflow "Highboy" - Side Return Installations  
Airflow
30° max.
45° max.
14
3
/
4
"
23
7
/
8
"
28
1
/
8
"
without door
11
1
/
2
"
door
door
17
3
/
4
"
24
7
/
8
"
31
1
/
8
"
with door
Outlet Side
Furnace Connection
Inlet Side
Return Duct Connection
Front
14
3
/
4
"
The Model 5000 Air Cleaner is designed for systems
with airflow up to 2000 cfm. If the furnace has
more than one return air inlet connection, install
one air cleaner in each.
The air cleaner can be installed horizontally, vertically,
or at an angle depending on furnace type. Figures
2, 3, and 4 show unit orientation in various types of
applications. Note airflow direction arrows on inner
assembly and outer housing.
Allow 29” clearance in front of the unit for media
replacement (see Figure 5).
If a transition or offsets are required, minimize
transition angles to reduce system pressure drop
(see Figure 4).  Figure 6 shows the air cleaner
dimensions. 
Figure 2
Figure 3
Figure 4
Figure 6
4
Allow Clearance for
Removal of Inner Housing
for Filter Replacement
Figure 5
Minimize Angles
Where Possible
Figure 5
APPLICATIONS WITH A HUMIDIFIER