Mitsubishi Electronics FX3GC ユーザーズマニュアル
918
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
Series
Programming Manual - Basic & Applied Instruction Edition
B Instruction Execution Time
B-1 Basic Instruction Execution Time
Output instructions
OUT Y,M
0.21
1.2
µs in 2-step instruction
OUT S
1.25
1.25
OUT T K
2.41
2.16
OUT T D
2.77
2.54
OUT C K
1.9
2.25
1.57
1.72
C235 to C255
1.6
1.6
µs in execution in ON status
1.06
µs in execution in OFF status
OUT C D
2.26
1.49
1.93
2.35
C235 to C255
2.21
2.21
µs in execution in ON status
1.06
µs in execution in OFF status
SET Y,M
0.23
1.25
µs in 2-step instruction
SET S
1.23 or 1.33 + 0.51n
0.59
n: Number of recombination
1.23
1.23
µs when there is no recombination
RST Y,M
0.23
1.22
µs in 2-step instruction
RST S
1.17
0.59
RST T
1.68
1.21
RST C
1.77
1.82
1.18
1.19
RST D
1.08
0.54
PLS Y,M
1.52
PLF Y,M
1.52
Master control instructions
MC
1.63
1.76
MCR
1.3
⎯
Other instruction
NOP
0.21
End instruction
END
209
⎯
Even if FEND and END are used
together, execution time of only END is
required.
together, execution time of only END is
required.
Instruction
Execution time in ON status (
µs)
Execution time in OFF status (
µs)
Remarks
16-bit instruction
32-bit instruction
16-bit instruction
32-bit instruction