ZyXEL Communications 2110 ユーザーズマニュアル
Z-Wave Series Programming Guide
8
C
H A P T E R
2
SHD1110 Programming
2.1 Z-Wave Groups (Association Command Class Version 2)
On the Z-Wave Controller, you can set the SHD1110 to send reports of itself (including power,
temperature, humidity, and battery status) to associated nodes of Grouping 1 or control
associated Z-Wave devices of Grouping 2. Grouping 1 supports one node and Grouping 2 supports
up to three nodes.
temperature, humidity, and battery status) to associated nodes of Grouping 1 or control
associated Z-Wave devices of Grouping 2. Grouping 1 supports one node and Grouping 2 supports
up to three nodes.
2.1.1 Grouping 1
Grouping 1 includes the following commands: POWER_APPLIED, SENSOR_MULTILEVEL
_REPORT, ALARM_REPORT and BATTERY_REPORT_COMMAND.
_REPORT, ALARM_REPORT and BATTERY_REPORT_COMMAND.
2.1.1.1 POWER_APPLIED command
When power is applied to the SHD1110, the ALARM_REPORT command will be sent to Grouping 1
to inform that the SHD1110 is powered up.
to inform that the SHD1110 is powered up.
2.1.1.2 MULTILEVEL_SENSOR_REPORT
The SHD1110 automatically sends out SENSOR_MULTILEVEL_REPORT, containing its current
temperature and humidity, to Grouping 1. Refer to the
temperature and humidity, to Grouping 1. Refer to the
section on
for settings of auto report configuration.
Humidity
The following parameters are used in this example:
Sensor Value 1 = 0x23
Humidity Value = Sensor Value = 35 (%)
ALARM_REPORT Command
[Command Class Alarm, Alarm Type = 0x02, Alarm Level = 0x01]
SENSOR_MULTILEVEL_REPORT
[Command Class Sensor Multilevel, Sensor Multilevel Report, Sensor Type = 0 x
05 (Relative Humidity), Precision+Scale+Size = 0 x 01, Sensor Value 1 = 20-
90%]