Avalon Stoves Flush Wood Insert ユーザーズマニュアル

ページ / 34
12
Installation 
(for qualified installers only)
© Travis Industries
100-01157
4041116
Surround Panel Installation
The surround panels are available in two sizes shown below.
Width
Height
Part#
8" Panels
45-1/2"
29-1/2"
99300240
10" Panels
49-1/2"
31-1/2"
99300241
12" Panels
53-1/2"
33-1/2"
99300242
FOR INSIDE FIT PANELS ONLY: the panels may be cut down to fit within the fireplace - see directions below.
Do not cut more than 4" 
from each side panel.
The rheostat is mounted 
into the side panel.  It 
requires 1/8" and 3/8" 
diameter holes to be 
drilled into the panel.  
Position the rheostat a 
minimum 3" away from 
the insert.
4" Min.
7/16"
1.  Before installing the side panels, position the insert over the hearth (not inside the fireplace).  You
may wish to place something under the insert to prevent scratching (cardboard).  Install the side
panels following the directions below.
Run the 
rheostat wires 
behind the 
surround panel 
(cut the lock-tie 
holding them in 
place).
Attach the surround panels with the 6 screws included with the fireplace insert.
HINT: Before installing the panels, pre-thread the holes in the side of the insert (use the self-
threading screws).
Run the power cord behind the surround panel 
(cut the lock-tie holding it in place).