Vermont Casting 3225 ユーザーズマニュアル

ページ / 44
15
Radiance Direct Vent /Natural Vent Gas Heater
20004188
Venting System Assembly - Direct Vent
General Information
The Radiance is approved for installation only with the 
vent components listed on Page 11. Follow the vent 
component instructions exactly.
For U.S. installations: The venting system must con-
form with local codes and/or the current National Fuel 
Gas Code, ANSI Z223.1/NFPA 54.
For Canadian installations: The venting system must 
conform to the current CSA B149.1 installation code.
Install the Vent Adapter Pipe 
(CFM Corporation Vent Components)
1.  Install the Restrictor Plate.  Consult Page 7, Figure 
8 to determine whether the restrictor plate is needed. 
If so, place the restrictor plate within the inner flue 
collar as shown in Figure 18.
ST647install restrictor plate
4/20/01   djt
ST647
Fig. 18  Install the restrictor plate only if required for the vent-
ing configuration. Refer to Page 7.
4.  Attach the Inner Vent Assembly to the stove.
•  Run a bead of sealant around the bottom end of 
the starter pipe and attach the assembly to the stove 
using three 1/4-20 x 3/8” Phillips screws provided in 
the parts bag. (Fig. 20)
2.  Attach Inner Starter Pipe, (found in with the log-
set), to the next section of inner pipe.  
•  Run a bead of sealant about 1/2” from the upper 
end of the Inner starter pipe and join the two sec-
tions together.
•  Drill three pilot holes into the Inner Starter and 
secure the assembly with three sheet metal screws. 
(Fig. 19)
3.  Dry fit the Inner Pipe assembly to the stove for 
the purpose of determining the center line of the 
pipe on the wall.
  Side Wall Terminations: Dry fit the outer elbow 
with the vertical outer vent and confirm the centerline 
alignment with the wall thimble opening.
CEMENT
ST211
attach inner pipe
to next section
12/4/99   djt
First Section of 
Vent Pipe
1/4”-20 x 1/2” 
Phillips Screw
4” Inner 
Starter 
Pipe
ST211
Fig. 19   Connect the inner starter with the next section of 
inner vent pipe.
Fig. 20  Attach inner assembly to flue collar.
ST648
ST647
attach inner assy
4/20/01   djt
CEMENT
5.  Install the Outer Adapter Pipe. Insert the pipe 
over the stove flue collar, keeping the vertical seam 
oriented to the back of the stove. Also, be sure to 
align holes on the pipe with the holes on the flue 
collar of the firebox. Fasten the pipe to the holes in 
the flue collar with the #12 x 1/2” sheet metal screws 
provided. (Fig. 21)