NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Electronic Models - 
Electronic models have a fixed rate gas valve.
Input of electronic models is shown in
Table 3.
Electronic Models with Fixed Rate Gas Valve
Natural and Propane Gas
Model Series
Input Rate
(BTU / HR)
LMDVT-3328
LMDVR-3328
17,500 
LMDV-3530
20,000 
LMDV-4035
27,000 
Table 3
Burner Orifice Sizes 
Elevation 0-4500 feet ( 0-1372 meters)
Model
Series
Nat.Gas
drill size (inches)
Propane
drill size (inches)
LMDVT-3328
LMDVR-3328
#45 (.082") 
*
39L66 •
(.048") 
*
99K780 
LMDV-3530
#44 (.086") 
*
60J8001 •
#55 (.052") 
*
19L5201
LMDV-4035
#37 (.104") 
*
24M1001 •
1/16" (.062")
*
21L0101 •
Table 7
Inlet Gas Supply Pressure 
(all models)
Fuel #
Minimum
Maximum
Natural Gas
5.0" WC
(1.24 kPa)
10.5" WC
(2.61 kPa)
Propane
11.0" WC
(2.74 kPa)
13.0" WC
(3.23 kPa)
Table 4
Gas Pressure - All Models
Tables 4, 5 and 6  show the appliances' gas
pressure requirements:
Manifold Gas Supply Pressure
(millivolt models)
Fuel #
Low
High
Natural 
Gas
(Lo) 2.2" WC
(.55 kPa)
(Hi) 3.5" WC
(.87 kPa)
Propane (Lo) 6.3" WC
(1.57 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 5
Manifold Gas Supply Pressure
(electronic models)
Fuel #
Maximum Manifold Pressure
Natural Gas
(Hi) 3.5" WC (.87 kPa)
Propane
(Hi) 10.0" WC (2.49 kPa)
Table 6
Test  gauge  connections  are  provided  on  the
front of the millivolt gas control valve, identi-
fied IN for the inlet and OUT for the manifold
side.    A  1/8"  NPT  Test  gauge  connection
is  provided  at  the  inlet  and  outlet  side  of
the electronic gas control valve.
Orifice Sizes -  Sea Level to High Altitude
(All Models)
These appliances are tested and approved for
installation at elevations of 0-4500 feet (0-1372
meters) above sea level using the standard burner
orifice sizes (marked with an "*" in Table 7). For
elevations above 4500 feet, contact your gas
supplier or qualified service technician .
Gas Valve Diagrams
See  Figures  1  &  2  for  Millivolt  models  and
Figure 3 For Electronic Models.
Figure 3
Honeywell Electronic  Gas Valve
FF
O
NI
P
S
I
N
O
L
O
RT
N
O
C
GI
N
TIER
Manifold Pressure 
Port
ON / OFF Switch
Inlet 
Pressure
Port
Electronic 
Gas 
Control 
Valve
O N
 
OFF
PIL
OT
LO
H
I
Figure 2
GAS CONTROL
KNOB
CONVERTIBLE
HI/LO REGULATOR
(adjusts flame height
and heat output)
INLET
PRESSURE
TAP
PILOT
ADJUSTMENT
SCREW
WIRING
TERM-
INALS
OUTLET
PRESSURE
TAP
TP/TH
PIEZO
IGNITER
TH
TP
Honeywell Millivolt  Gas Valve
These appliances must be isolated from the
gas supply piping system (by closing their 
individual manual shut-off valve) during any
pressure  testing  of  the  gas  supply  piping
system at test pressures equal to or less than 
1/2 psig (3.5 kPa).
These appliances and their individual shut-off
valves must be disconnected from the gas
supply  piping  system  during  any  pressure
testing of that system at pressures greater 
than 1/2 psig (3.5 kPa).
Install the appliance according to the regulations
of the local authorities having jurisdiction and,
in the USA, the National Fuel Gas Code NFPA 54
/ ANSI Z223.1 - latest edition or, in Canada, the
CAN1-B149.1 and .2 codes - latest edition.
 Input (BTU) Manually-Modulated Gas 
Valves (millivolt models)
NATURAL GAS
Models
Input Rate (BTU / HR)
LMDVT-3328CNM
LMDVR-3328CNM
17,500 high
11,700 low
LMDV-3530CNM
20,000 high
12,800 low
LMDV-4035CNM
27,000 high
18,500 low
Table 1
 Input (BTU) Manually-Modulated Gas 
Valves (millivolt models)
PROPANE GAS
Models
Input Rate (BTU / HR)
LMDVT-3328CPM
LMDVR-3328CPM
17,500 high
14,000 low
LMDV-3530CPM
20,000 high
15,200 low
LMDV-4035CPM
27,000 high
21,500 low
Table 2
HI
LO W
HT
PT
HT
PT
PILO
T
PIL
OT
ON
it
OFF
IN
OUT
Manifold Pressure Tap
Inlet Pressure Tap
SIT Millivolt  Gas Valve
Pilot Adjustment
Screw
HI/LO Variable 
Flame Height 
Adjustment
Main Gas 
Control Knob
OFF/PILOT/ON
Figure 1
* Standard size installed at factory
•  Part /Cat. Number