Lennox Hearth MPD-4035CPM-B ユーザーズマニュアル

ページ / 42
5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LENNOX HEARTH PRODUCTS  •  MERIT
®
 PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45)  •  INSTALLATION INSTRUCTIONS
HORIZONTAL VENT
(Rear Vent Application with a chase)
HORIZONTAL VENT
(Top Vent Application)
VERTICAL VENT
(Top Vent Application)
(Rear Vent Application)
VERTICAL VENT
(Rear Vent Application without a chase)
HORIZONTAL VENT
LOCATION
In  selecting  the  location,  the  aesthetic  and 
functional  use  of  the  appliance  are  primary 
concerns.  However,  vent  system  routing  to 
the exterior and access to the fuel supply are 
also important.  
due  to  high  temperatures,  the  appliance 
should be located out of traffic and away from 
furniture and draperies (Figure 3). 
En  raison  des  températures  élevées, 
l’appareil  devrait  être  installé  dans  un 
endroit où il y a peu de circulation et loin 
du mobilier et des tentures (Figure 3).
The location should also be free of electrical, 
plumbing  or  other  heating/air  conditioning 
ducting.
These  direct-vent  appliances  are  uniquely 
suited for installations requiring a utility shelf 
positioned  directly  above  the  fireplace.  Util-
ity shelves like these are commonly used for 
locat-ing television sets and decorative plants.
Be  aware  that  this  is  a  heat  producing  ap-
pliance.  Objects  placed  above  the  unit  are 
exposed to elevated temperatures.
do not insulate the space between the appli-
ance and the area above it (see Figure 8 ).
The minimum height from the base of the appli-
ance to the underside of combustible materials 
used to construct a utility shelf in this fashion 
is shown in Figure 8.  
The  appliance  should  be  mounted on  a fully 
supported  base  extending  the  full  width  and 
depth of the unit. The appliance may be located 
on or near conventional construction materials. 
However, if installed on combustible materials, 
such as carpeting, vinyl tile, etc., a metal or 
wood barrier covering the entire bottom surface 
must be used.
COLd CLIMATE INSULATION
For cold climate installations, seal all cracks 
around  your  appliance  with  noncombustible 
material  and  wherever  cold  air  could  enter 
the room. It is especially important to insulate 
outside chase cavity between studs and under 
floor on which appliance rests, if floor is above 
ground level.  Gas line holes and other open-
ings should be caulked or stuffed with unfaced 
fiberglass insulation.  
If the fireplace is being installed on a cement 
slab in cold climates, a sheet of plywood or 
other raised platform can be placed underneath 
to prevent conduction of cold transferring to 
the fireplace and into the room.  It also helps to 
sheetrock inside surfaces and tape for maximum 
air tightness and caulk firestops.
MANUFACTUREd HOME 
REQUIREMENTS
This appliance may be installed in an aftermarket 
permanently located, manufactured home and 
must be installed in accordance with the manu-
facturer's instructions and the Manufactured 
Home Construction and Safety Standard, Title 
24 CFR, Part 3280, in the United States, or the 
Standard for Installation in Mobile Homes, CAN/
CSA Z240 MH Series, in Canada. 
Cet  appareil  peut  être  installé  cómme 
du  matéri-el  d'origine  dans  une  maison 
préfabriquée  (É.U.  seulement)  ou  mobile 
et doit être installé selon les instructions 
du fabricant et conformément à la norme 
Manufactured  Home  Constructions  and 
Safety,  Title  24  CFR,  Part  3200  aux  Unis 
ou  à  la  norme  Can/CSA-Z240  Série  MM, 
Maisons mobiles au Canada. 
This appliance is only for use with the type of gas 
indicated on the rating plate.  This appliance is 
not convertible for use with other gases, unless 
a certified kit is used.
Cet  appareil  doit  être  utilisé  uniquement 
avec le type de gaz indiqué sur la plaque 
signalétique.    Cet  appareil  ne  peut  être 
converti à d'autres gaz, sauf si une trousse 
de conversion est utilisée.
CAUTION:  Ensure  that  the  cross  mem-
bers  are  not  cut  or  weakened  during 
installation.  The  structural  integrity  of 
the manufactured home floor, wall, and 
ceiling / roof must be maintained. 
CAUTION: This appliance must be ground-
ed  to  the  chassis  of  the  manufactured 
home in accordance with local codes or 
in the absence of local codes, with the 
National Electrical Code ANSI / NFPA 70 
- latest edition or the Canadian Electrical 
Code CSA C22.1 - latest edition. 
Figure 3: Typical Locations
 APPLICA
TION
REAR VENT
 APPLICA
TION
TOP VENT
 APPLICATION
TOP VENT
REAR VENT  APPLICA
TION
TOP VENT  APPLICA
TION
RECESSED
INSTALLATION
TOP VENT
 APPLICATION
 APPLICA
TION
TOP VENT
 APPLICA
TION
TOP VENT