prEcautIons
Note: These fireplace systems are not difficult 
to install. However, in the interest of safety, it 
is recommended that the installer be a qualified 
or  certified  “tradesman”  familiar  with  com-
monly accepted fireplace installation and safety 
techniques as well as prevailing local codes.
The most important areas of concern dealing 
with the installation of factory-built fireplaces 
are clearances to combustible materials, proper 
assembly  of  component  parts,  height  of  the 
chimney system, the proper use of accessories 
supplied by the manufacturer and the techniques 
employed in using finishing materials applied 
to  the  wall surrounding  the  fireplace,  hearth 
extensions and wall shields. Each of these topics 
will be covered in thorough detail throughout 
this manual. Please give each your special at-
tention as you progress with your installation.
Important notEs: 
  WhEn  InstallIng  In  canada  (Est-36 
and Est-42 only), thE cold clImatE KIt 
must bE InstallEd pEr thE WarnocK 
hErsEy lIstIng (see Step 6 on page 12 
and “Installation Components” on page 24.
  thE  mInImum  aIr  spacE  to  combus-
tIblEs for thE chImnEy systEm Is 2" 
(51mm).
  thE ftf13 chImnEy systEm Is not for 
usE In canada. modEl Est-50 Is not 
for usE In canada.
IntroductIon
general Information
These fireplaces are conventional radiant heat 
fireplaces  with  standard  bar  grates,  optional 
outside combustion air kits and optional decora-
tive glass doors.
Note: Illustrations reflect “typical” installations 
with nominal dimensions and are for design 
and framing reference only. Actual installations 
may vary due to individual design preferences. 
However, always maintain minimum clearances 
to combustible materials and do not violate any 
specific installation requirements.
models Est-36 and Est-42 have been tested 
and listed to U.L. 127 standard for U.S. instal-
lations and U.L.C. S610 standard for Canadian 
installations by Warnock Hersey Inc. (Report 
No. J20054576-231). model Est-50 has been 
tested and listed to U.L. 127 standard for U.S. 
installations by PFS-US (Report No. 09-185) 
for EST-50. 
These  units  are  intended  for  installation  in 
residential homes and buildings of conventional 
construction, not in mobile homes.
These fireplace systems are designed for in-
stallation in accordance with the National Fire 
Protection Standard for chimneys, fireplaces 
and solid fuel burning appliances; NFPA 211 
and in accordance with codes such as the BOCA 
Basic/National Codes, the Standard Mechani-
cal Code, Uniform Building Codes and/or the 
Canadian National Code. 
clEarancEs and hEIght
rEquIrEmEnts
The fireplace may be placed on or near normal 
construction materials.* The combustion air kit, 
firestop spacer and roof flashings (not chase 
flashings) may be placed directly on or against 
normal construction materials.* The chimney 
requires a minimum 2" (51 mm) air space to 
combustibles. A combustible mantel may be 
installed a minimum of 12" (305 mm) above 
the opening of the fireplace as per NFPA 211, 
“Mantel/Trim Clearances” Section. In Canada the 
minimum is 24" (610 mm) above the opening.
The  fireplace  and  chimney  system  must  be 
enclosed when installed in or passing through 
a living area where combustibles or people may 
come in contact with it. This is important to 
prevent possible personal injury or fire hazard.
For questions, please call your distributor or 
the manufacturer. Special restrictions apply to 
the front and facing of the fireplace and nearby 
walls (see pages 20 and 21).
chImnEy systEm
These fireplaces are designed and code listed for 
use with Security Chimneys FTF10 and FTF13 
chimney  System  only.  Always  use  Security 
Chimneys FTF10 and FTF13 chimney compo-
nents with these fireplaces. Do not modify or 
alter  these  components  as  this  may  cause  a 
potential serious hazard and void the Warranty.
*Construction Materials:
 • framing materials
 • paneling
 • particle board
 • flooring
 • drywall
 • plywood
 • noncombustible insulation board  
    (for hearth)
When complete, these fireplace systems consist 
of five basic “sub-systems”:
1.  Fireplace
2.  Chimney and Termination
3.  Optional Glass Doors 
4.  Optional Combustion Air Kit
5.  Chimney Collar Enclosure Kit (Canada only)
       WarnIng 
failure  to  use  manufacturer- 
provided  parts,  variations  in 
techniques  and  construction 
materials,  or  practices  other 
than  those  described  in  this 
manual may create a fire hazard 
and void the limited warranty.
Optional Position
for Cold Climate Kit
(Canada Only)
Cold Climate Kit
(Canada Only)
Outside
Combustion
Air Kit
(Optional)
Chimney and
Termination
Figure 1: Typical Installation