Vent Parts List - Horizontal
Direct  vent  pipe  by  Security™  or  Simpson  Dura-Vent  may  be  used
with the Ravelle™ 42 gas fireplace. Please see the lists below to verify
the components available from each direct vent pipe manufacturer. All
horizontally terminated venting of the Ravelle 42 gas fireplace uses 8”
x 5” size vent pipe and all vertically terminated venting uses 6-5/8” x 4”
size vent pipe. The flue collar on the fireplace is 8” x 5” in size. Therefore,
when vertically terminating it is necessary to use a reducer - part number
75247 (available from Lennox Hearth Products) - to make the transition
from the 8” x 5” flue collar to the 6-5/8” x 4” pipe. Snorkel terminations
are available for applications which may require vertical rise on the building
exterior. The components listed below come in a galvanized finish. Most
of the components are also available in a painted black finish. Add a “B”
to the end of the part number when ordering if a black part is desired.
Security™ Secure Vent™ 8”x 5” Pipe 
Part Number 
Description
SV5L6
6” Pipe Length
SV5L12
12” Pipe Length
SV5L24
24” Pipe Length
SV5L36
36” Pipe Length
SV5L48
48” Pipe Length
SV5LA
6” Pipe, Adjustable
SV5LA12
12” Pipe, Adjustable
SV5E45
45º Elbow
SV5E90
90º Elbow
SV5RSM
Wall Radiation Shield
SV5VS
Vinyl Shield Protector
SV5BF
Firestop
SV5CHC-1
Horizontal Termination Cap
SV5STC14
Snorkel Termination (14”) Cap
SV5STC36
Snorkel Termination (36”) Cap
SV5BM
Wall Band
Simpson Dura-Vent GS 8”x 5” Pipe
Part Number   
Description
1208
6” Pipe Length
1207
9” Pipe Length
1206
12” Pipe Length
1204
24” Pipe Length
1203
36” Pipe Length
1202
8” Pipe Length
1211
11” to 14-5/8” Pipe, Adjustable
1217
17” to 24” Pipe, Adjustable
1290
90° Elbow
1247
Wall Thimble
1263
Ceiling Firestop
1288
Wall Strap
1281
Snorkel Termination (36”)
1282
Snorkel Termination (14”)
1284
Horizontal Termination Cap
1285
Horizontal Termination Cap (High Wind)
1250
Vinyl Siding Standoff
Vent Parts List - Vertical
Direct vent pipe by Security or Simpson Dura-Vent may be used with
the  Ravelle  42  gas  fireplace.  Please  see  the  lists  below  to  verify  the
components  available  from  each  direct  vent  pipe  manufacturer.  All
horizontally terminated venting of the Ravelle 42 gas fireplace uses 8”
x 5” size vent pipe and all vertically terminated venting uses 6-5/8” x 4”
size vent pipe. The flue collar on the fireplace is 8” x 5” in size. Therefore,
when vertically terminating it is necessary to use a reducer - part number
75247 (available from Lennox Hearth Products) - to make the transition
from the 8” x 5” flue collar to the 6-5/8” x 4” pipe. Snorkel terminations
are available for applications which may require vertical rise on the building
exterior. The components listed below come in a galvanized finish. Most
of the components are also available in a painted black finish. Add a “B”
to the end of the part number when ordering if a black part is desired.
Security Secure Vent 6-5/8”x 4” Pipe 
Part Number 
 
Description
SV4L6  
6” Pipe Length
SV4L12  
12” Pipe Length
SV4L24  
24” Pipe Length
SV4L36  
36” Pipe Length
SV4L48  
48” Pipe Length
SV4LA  
6” Pipe, Adjustable
SV4LA12
12” Pipe, Adjustable
SV4FA  
Flashing, 1/12 to 176/12 Roof Pitch
SV4FB  
Flashing, 8/12 to 12/12 Roof Pitch
SV4RSM  
Wall Radiation Shield
SV4E46  
45° Elbow
SV4E90  
90° Elbow
SV4VS  
Vinyl Shield Protector
SV4FC  
Storm Collar
SV4CGV  
Vertical Termination Cap
SV4BF  
Firestop
SV4BM  
Wall Band
Part Available from Lennox Hearth Products Only:
75247
8” x 5” to 6-5/8” x 4” Reducer
Simpson Dura-Vent GS 6-5/8” x 4” Pipe
Part Number   
 
Description
908  
6” Pipe Length
907  
9” Pipe Length
906  
12” Pipe Length
904  
24” Pipe Length
903  
36” Pipe Length
902  
48” Pipe Length
911  
11” to 14-5/8” Pipe, Adjustable
912  
12” to 17” Pipe, Adjustable
917  
17” to 24” Pipe, Adjustable
942  
Wall Thimble
945  
45° Elbow
943  
Flashing, 0/12 to 6/12 Roof Pitch
943S
Flashing, 7/12 to 12/12 Roof Pitch
953  
Storm Collar
963  
Ceiling Firestop
988  
Wall Strap
980  
Vertical Termination Cap
991  
Vertical Termination Cap (High Wind)