NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
TO TURN OFF GAS TO APPLIANCE
1. Turn off the "ON/OFF" rocker switch and/or thermostat (if in-
stalled) to its lowest setting.
2.  Turn  off  electric  power  to  the  appliance  if  service  is  to  be
performed.
3. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
This appliance needs fresh air for safe operation and must be 
installed so there are provisions for adequate combustion and 
ventilation air. 
SHUTDOWN PROCEDURE
To turn off the burner, turn the rocker switch to "OFF" or adjust
the thermostat (if installed) to a setting below room temperature.
The pilot will remain lit for future burner ignition. For complete
shutdown, see "TO TURN OFF GAS TO APPLIANCE" above.
Flame Color and Behavior
Your Ravelle™ 42 gas fireplace is designed for maximum heating ef-
ficiency. Therefore, upon lighting of the main burner the flames will be
semi-transparent or “bluish.” After 10-20 minutes of operation the logs
will heat up and the flames will become a yellow/orange color.
Adjusting the fireplace to cause the flames to turn orange sooner may
result in poor combustion, sooting and a hazardous situation. See Figure
45
showing proper flame appearance.
When testing for proper operation - If an optional thermostat is installed
adjust it to its highest temperature setting. Visually determine that main
burner gas is burning properly: i.e., no floating, lifting or flashback.
Adjust  the  primary  air  shutter(s)  as  required.  Check  for  proper  main
burner operation at both high and low flame.
PILOT ASSEMBLY
Thermopile
Veilleuse à gaz Igniter (electrode)
Allumeur
Thermocouple
Gas Pilot Hood
TP/TH
TH
TP
Gas Control Knob 
(Pilot / On / Off)
O
FF
O
N
Piezo Igniter
Allumeur
ON/OFF Switch
Interrupteur
Flame Height Control 
Knob (HI/LO)
No Blue Flame 
Center
Soot at 
Flame Tip
Dark Orange 
Flame
IMPROPERLY 
BURNING FLAME
Soot above 
Flame Tip
No Soot at 
Flame Tip
PROPERLY
BURNING FLAME
Semi-Transparent 
Yellow Flame 
Blue Flame 
Center
Ports on Burner 
Assembly
Burner Flame Appearance
Figure 44
Figure 45
SIT Millivolt Gas Valve
       WARNINGS
Improper installation, adjustment, alteration, 
service  or  maintenance  can  cause  injury  or 
property damage. For assistance or additional 
information, consult a qualified installer, service 
agency or your gas supplier.
Operation of this appliance when not connected 
to a properly installed and maintained venting 
system  can  result  in  carbon  monoxide  (CO) 
poisoning and possible death.
Carbon  monoxide  poisoning  –  Early  signs  of 
carbon  monoxide  poisoning  resemble  the  flu 
with headaches, dizziness, or nausea.  If you 
have these signs, get fresh air at once!  Have 
the  heater  inspected  by  a  qualified  service 
technician.  Some people are more affected by 
carbon monoxide than others.  These include 
pregnant  women,  people  with  heart  or  lung 
disease or anemia, those under the influence 
of alcohol and those at high altitudes.