Lennox Hearth LMDV-4035-CNE ユーザーズマニュアル

ページ / 36
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
2
TABLE OF CONTENTS 
Packaging .........................................Page  2
Introduction ......................................Page  2
General Information ..........................Page  2
New York City Approval .....................Page  3
Requirements for the
Commonwealth of Massachusetts .Page  4
Cold Climate Insulation .....................Page  4
Location ............................................Page  4
Manufactured Home Requirements ..Page  5
Vent Termination Clearances ............Page  5
Appliance and Vent Clearances .........Page  7
Detailed Installation Steps .................Page  8
Typical Installation Sequence ...........Page  8
Step 1. Framing .................................Page  8
Step 2. Routing Gas Line ..................Page  8
Fireplace Specifications .....................Page  9
Step 3. Install the Venting System ....Page  11
Vertical Termination Systems ............Page  12
Vent Section Length Chart ................Page  12
Vertical Vent Tables and Figures ........Page  14
Horizontal Termination System .........Page  16
Horizontal Vent Tables and Figures ...Page  19
Venting Using Flexible Vent Pipe .......Page  22
Step 4.  Field Wiring .........................Page  23
Step 5.  Optional Blower Kit Wiring ..Page  23
Step 6.  Connecting Gas Line ...........Page  24
Step 7.  Checking Unit Operation .....Page  25
Step 8.  Installing Logs ...................Page  26
Step 9.  Installing Glass Door ..........Page  29
Step 10. Burner Adjustments ............Page  29
Step 11. Hood Installation .................Page  30
Finishing Requirements ....................Page  30
Installation Accessories ....................Page  31
Gas Conversion Kits .................. Page  34
INTRODUCTION 
These  vented gas fireplace  heaters  are sealed
combustion,  air  circulating  gas  fireplaces  de-
signed for residential applications.
Approved Vent Components - These fireplaces
are designed, tested and listed for operation
and installation with, the following vent com-
ponents only:
 
Secure Vent™ Direct Vent System Compo-
nents,
 
Secure  Flex™  Flexible  Vent  Components
manufactured  by  Security  Chimneys  Inter-
national and
 
Z-FLEX™ Model GA Venting Systems listed
to UL1777 and ULCS635 manufactured by
Flexmaster Canada Limited.
These approved vent system components are
labeled for identification. DO NOT use any other
manufacturer’s  vent  components  with  these
appliances. Use only the correct size venting
(4-1/2" inner & 7-1/2" outer).
These  appliances  comply  with  National  Safety
Standards  and  are  tested  and  listed  by  OMNI-
Test Laboratories, Inc. (Report No. 116-F-31-5)
to ANSI Z21.88b (in Canada, CSA-2.33b), and
CAN/CGA-2.17-M91 in both USA and Canada,
as vented gas fireplace heaters.
Both  millivolt  and  electronic  versions  of 
these  appliances are listed by OMNI-Test 
Laboratories  for  installation  in  bedrooms 
and Manufactured Homes.
Manufactured Homes - 
See  Manufactured  Home  Requirements  on 
Page 5  for additional information.
PACKAGING
The assembled vented gas fireplace heater is
packaged with:
1 - One log set located in firebox area.
2 - One envelope containing the literature pack-
age  which  consists  of  the  homeowner's
manual, installation instructions, and war-
ranty;  envelope  is  located  in  the  control
compartment.
3 - One vent restrictor to be applied as shown on
Page 11 ; restrictor is taped to the envelope.
4 - One hood located behind the top panel.
5 - One bag of decorative volcanic stone located
in the control compartment.
6 - One bag of glowing embers located in the
control compartment.
7 - One bag of vermiculite located in the control
compartment.
 
       WARNING 
Improper  installation,  adjust-
ment,  alteration,  service  or 
maintenance  can  cause  injury 
or property damage.  Refer to 
this manual.  For assistance or 
additional  information  consult 
a  qualified  installer,  service 
agency or the gas supplier.
This appliance is only for use with the type 
of gas indicated on the rating plate. This ap-
pliance is not convertible for use with other 
gases, unless a certified kit is used.
Cet  appareil  doit  être  utilisé  uniquement 
avec les types de gaz indiqués sur la plaque 
signalétique.  Ne pas l'utiliser avec d'autres 
gaz sauf si un kit de conversion certifié est 
installé.
Misc. Codes / Standards - 
Installation must conform to local codes. In the
absence of local codes, installation must comply
with the current National Fuel Gas Code, ANSI
Z223.1. (In Canada, the current CAN-1 B149
installation code).
The appliance, when installed, must be elec-
trically grounded & wired in accordance with
local codes or, in the absence of local codes,
with the National Electrical Code, ANSI / NFPA
70-latest  edition,  or  the  Canadian  Electrical
Code, CSA C22.1 - latest edition.
GENERAL INFORMATION
Note:  Installation  and  repair  should  be  per-
formed  by  a  qualified  service  person.  The 
appliance should be inspected annually by a 
qualified professional service technician. More 
frequent  inspections  and  cleanings  may  be 
required due to excessive lint from carpeting, 
bedding material, etc. 
S'assurer que le brùleur et le compartiment des 
commandes sont propres.  Voir les instructions 
d'installation et d'utilisation qui accompagnent 
l'appareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
These appliances are designed to operate on 
natural or propane gas only. The use of other 
fuels  or  combination  of  fuels  will  degrade 
the performance of this system and may be 
dangerous. 
These fireplaces are designed as supplemen-
tal heaters. Therefore, it is advisable to have
an  alternate  heat  source  when  installed  in  a
dwelling.
Millivolt Models - The millivolt appliances are
manually controlled and feature a spark igniter
(piezo) that allows the appliance's pilot gas to
be lit without the use of matches or batteries.
This system provides continued service in the
event of a power outage.
Millivolt models come standard with a manu-
ally-modulated gas valve; flame appearance and
heat output can be controlled at the gas valve.
The BTU Input for these appliances is shown
in Tables 1 & 2.
The  Millivolt  appliances  have  a  millivolt  gas
control valve with piezo ignition system which
provides safe, efficient operation. If any optional
accessories  that  will  require  electrical  power
are to be installed, the electrical power must be
provided at the time of appliance installation.
The
Electronic appliances have an electronic
intermittent pilot ignition system which provides
safe, efficient operation. External electrical pow-
er is required to operate these appliances.
This manual is part of a set of two supporting
this product. Refer to manual 875,028M for
Care & Operation information.
Please read and understand these 
instructions before beginning your 
installation.