5.  Install the facade onto the fireplace face per instructions in Figure 3.
6. See  Figure  4  for  instructions  on  accessing  the  control  compart-
ment. 
To  access  the  control  compartment,  pull  the  hinged  door 
forward and up as shown. To close, hinge the door closed 
until magnets secure it in place.
Figure 4 - Opening the Control Compartment Panel
Figure 5 - Completed Installation
IMPORTANT NOTE (Gold and Nickel Finishes Only):  The gold 
and nickel finishes will require heat to harden and cure (after 
approximately 3 fires, the finish will be completely cured).  Prior 
to burning this appliance the gold and nickel surfaces should be 
cleaned thoroughly with a good window cleaning solution and a 
soft cloth. Do not use any metal polishes or abrasives to clean 
the surfaces. Any oils or fingerprints left on the finish during the 
curing process may become permanent blemishes.
Magnets
Control Compartment
Control Compartment Panel
Facade
3. Using a 3/8” socket or nutdriver, install the upper filigree inset, lower 
filigree inset, screen and screen retainer with provided washers and 
nuts as shown in Figure 2. Note: you will have four extra washers 
and nuts.
4. Reinstall heat shield aligning the top corners of the heat shield with 
the etch marks in the back of the facade for proper placement. Do not 
over tighten nuts.
Figure 2
Brushed Nickel 
Facade Shown
Figure 3 - Install Facade
Tabs on Bracket 
Assemblies  (2 
places each side)
Slots on Fireplace    
(2 places each side)
Facade
Align  the  tabs  on  the 
bracket assemblies all 
the way into the slots 
on fireplace, then push 
facade down to ensure 
engagement.
Printed in U.S.A. © 2008 Lennox Hearth Products
p/N  750,231M  REV.  NC  06/2008
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and the discontinuance of colors, styles and products. 
Consult your local distributor for fireplace / insert code information.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Lennox hearth products
1110 west Taft Avenue • Orange, CA  92865
Note: There are two mount-
ing positions on the facade 
hanging brackets to better 
accommodate a range of 
facing thicknesses.  Adjust 
to the notch on the hanging 
bracket that works best for 
your installation. 
heat Shield
Upper Filigree
Lower Filigree
Screen
Screen Retainer
Etch 