Martin Fireplaces 400BWBCA ユーザーズマニュアル

ページ / 44
20 
61D0008
Rise
6'
(Maximum Offset)
ELBOW INSTALLATION 
(CONTINUED)
3.  The number of elbows per chimney allowed are as follows: 
 
If the total height of the fireplace and chimney is 13' 6" 
or more, two (2) elbows may be used. 
 
If the total height of the fireplace and chimney is 20' or 
more, four (4) elbows may be used. 
4.  Inclined portions of chimney is often used as storage. 
Enclose the inclined portions of chimney that pass through 
living spaces to avoid contact with and possible damage 
to chimney. Maintain minimum air space of 2" between 
chimney and enclosing. See Figures 22 and 23.
CHIIMNEY INSTALLATION 
Figure 22 - Installing Chimney with Total Height of 
Fireplace and Chimney 13' or More 
Figure 23 - Installing Chimney with Total 
Height of Fireplace and Chimney 20' or More
Continue Chimney to 
Proper Height and 
Install Round 
Chimney Cap or 
Chimney 
Housing 
Center Line 
Storm Collar 
Flashing
Roof
Center Line 
SF Firestop Spacer 
— 2" min. Air 
Space Clearance to 
Combustibles
SF Firestop Spacer 
2" min. Air Space 
Clearance to 
Combustibles
Vertical Chimney 
Enclosure
Support Straps 
 Support 
Straps 
Note: Two (2) 
elbows may be 
used when total 
installation height 
is more than 13'. 
Vertical Chimney 
Enclosure
Note: Chimney 
must be enclosed 
in accessible 
areas
Support Straps 
Note: Do not let support 
straps penetrate firestop 
Note: Vertical 
chimney enclosure 
is recommend.
Diagonal chimney 
enclosure is 
acceptable. 
Diagonal 
Chimney 
Enclosure
Support Strap 
5.  The length of inclined portion of chimney between elbows must not exceed 6' if elbows are not supported. 
 
The length of inclined portion of chimney between elbows must not exceed 20' if elbows are supported every 6' with 
metal support straps.
6.  When enclosing the elbows and inclined portions of the chimney, enclosing materials must be installed vertically to 
maintain the required 2"minimum air space clearance to the chimney at the extremities of the offset. It is best that enclos-
ing material not follow inclined portions of chimney. 
 
Note: Four (4) elbows may be used when total installation 
height is more than 20'. Four (4) is the maximum number of 
elbows allowed.