GAS APPLIANCE INSTALLATION 
2.  An approved gas shut off valve must be located outside the fireplace in an area accessible to the users of the fireplace. 
3.  All gas piping and fitting must be either steel or malleable iron. Unions must be of the ground joint type.
4.  Some code authorities prohibit or place restrictions on the use of gas appliances in fireplaces. Check with local code 
authorities before proceeding with installation.
5.  The gas appliance and all connecting gas piping must only be installed by a licensed gas appliance installer. See Figure 
36 for the gas line opening dimensions on the fireplace. 
6.  The installer of the fireplace and gas appliance must describe the operation of the fireplace and appliance to the people 
who will be operating them and leave all instruction manuals with the operator of the appliance. 
If an unvented gas appliance is installed in the fireplace, the gas appliance must 
only be operated with the fireplace glass door fully open (if included). Only unvented 
gas log sets which have been found to comply with the standard for unvented room 
heaters, ANSI/IAS/AGA Z21.11.2 are to be installed in this fireplace. 
CAUTION 
28"max.
Fireplace 
Opening 
Side Brick 
Inner Fireplace Wrap 
Outer Fireplace Wrap 
Maintain ½"min. Air 
Space Clearance to 
Combustibles for Gas 
Line Out to 4" from 
Side of Fireplace 
Figure 36 - Gas Line Opening Dimensions 
Hearth Brick 
Gas Line 
Access Tube 
Combustive Materials May Be 
Located at Zero Clearance to Gas 
Line Beyond 4" from Fireplace Side 
Do not operate an 
unvented gas log set in 
this fireplace with the 
chimney removed. 