Martin Fireplaces 400BWBCIA ユーザーズマニュアル

ページ / 44
61D0008 
17
CHIMNEY INSTALLATION
LOCATING CENTER LINE 
You will need to lay out, cut and frame openings through all ceilings 
and the roof at the point where the chimney will pass through.  
Place fireplace in planned position for installation. Unless the chimney 
is to be offset, the point where the center line of the chimney will pass 
through the ceiling and roof can be determined with a plumb line. See 
Figure 16. Drive a nail in the center point.
Note:  Make  sure  the  chimney  location  is  well  away  from 
ceiling and roof joists and/or anything else that might 
be in the way. 
Drive a long nail through the roof from underneath to mark the roof 
opening center line. Make sure the nail is long en ought to go through 
the roof and be seen on the rooftop. If the chimney is to penetrate a 
pitched roof, the hole in the roof must be rectangular instead of square 
and should be sized according to Table 1.
INSTALLING FIRESTOP SPACER
Install the firestop spacer from beneath the ceiling as shown in Figure 17 unless the space above is attic space. 
In an attic, install firestop spacer at the floor level of attic. You must have joists or headers on all four sides of the spacer. 
Use a minimum of four (4) 8-penny nails to secure the spacer. See Figure 18
Figure 16 - Dropping Plum Line 
from Ceiling 
Center Line 
to Chimney 
Actual 
Center Point 
Plumb 
Line 
Plumb 
Bob 
Imaginary 
Center 
Point 
Figure 18 - Installing Firestop Spacer 
at Attic Level 
Figure 17 - Installing Firestop Spacer 
at Floor Level 
Ceiling Joist 
Inlet Air Pipe
Flue Pipe
Floor Joist 
Header
Firestop Spacer 
Chimney Section 
Inlet Air Pipe
Flue Pipe
Header
Firestop 
Spacer 
Chimney Section