CHIIMNEY INSTALLATION 
OFFSET INSTALLATION SEQUENCE
 
(CONTINUED) 
1.  Install the first SE30 elbow by placing the extended flue into the mating 
part of the fireplace or chimney section. Push down until the outside of 
inlet air duct of the elbow overlaps. Snap lock the elbow into the fireplace 
or chimney section.
2.  Nail the support straps to the framing member with a minimum of two (2) 
8-penny nails per strap.
3.  Install the sections of pipe between elbows until the proper number of 
chimney sections have been installed.
4.  Install the second elbow to return the run of the chimney to vertical.
5.  Nail the support straps of the second elbow to a building frame member.
6.  Continue installing the vertical portion of the chimney. See Figures 22 
and 23.
Chimney 
Center Line 
Figure 23 - SF30 Firestop 
Spacer 
Note: If the inclined portion of the chimney passes through a floor or ceiling, an SF30 firestop spacer should 
be installed to provide the firestop and support required. Be sure proper spacing in maintained 
between the chimney and combustibles. See Figure 23.
CHIMNEY CAP INSTALLATION
MODEL SC CHIMNEY CAP
Note: The proper chimney height is important to assure proper draft and safety.The chimney cap must 
extend  the  flue  outlet  4"  above  the  top  of  the  last  section  of  chimney.  Keep  this  mind  when 
determining the proper height for the chimney. The chimney should not be extended more than 
90" above the supporting roof structure without additional support. In the case of an “A” frame 
type construction or other steep pitch roofs that require more than 90" of chimney above the roof, 
attach a support to the chimney at the 90" level that is strong enough to support a wind load of 
3
1
/
8
 pounds for each inch the chimney extends above 90". The flue outlet must be a minimum of 3' 
above the point where in penetrates the roof. See Figure 24.
Figure 24 - Proper Chimney Height