OUTSIDE COMBUSTION AIR PRECAUTIONS AND RECOMMENDATIONS
COMBUSTION AIR 
1.  Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any manner. 
Locate assembly above the snow line to prevent blockage by snow accumulation.
2.  Never mount the combustion air inlet assemblyin a garage or storage area where combustible fumes such as gasoline 
might be drawn into the fireplace.
3.  Combustion air can be drawn from the crawl space under a house when an adequate supply of air is provided by open 
ventilation.
4.  Do not take combustion air from attic space or garage space.
5.  Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly. 
These conditions increase the resistance to the free flow of air through the duct. See Figures 28 through 31 for methods 
of installing the outside air for combustion assemblies.
Continued 
Figure 28 - Basement Installation 
Figure 29 - Concrete Slab Installation 
(Optional Outside Air Runs)
Above 
Snow
Level
Ground 
Level 
Plate
Basement 
Wall 
Termination Cap 
Firestop Spacer
Inlet Grill 
in Soffit
(Overhang)
Do not take combustion 
air from attic space or 
garage. 
CAUTION