TRIM AND MANTEL INSTALLATION FOR GAS APPLIANCES 
Mantel Trim Installation (Unvented Gas Appliances Only)
The fireplace face may be left exposed or trimmed. If trim is installed, fasten it securely to face of fireplace. Trim materials 
must not extend closer than 
3
/
8
" to the vertical edge of fireplace opening if you plan to use glass doors. 
1.  Install hood on fireplace with mantels 12" from the 
opening of fireplace. Mantel may be no more than 
12" deep. Combustible framing members may be 
placed across top spacers. See Figure 38. 
2.  Combustible mantel and/or trim may be installed 
within shaded area in Figure 39. Use only non-
combustible materials below top of spacers and 
behind front face. 
Note: These instructions are for acceptable combustible mantel location in GAS APPLIANCES ONLY. See 
Figures 40 through 41 for acceptable combustible mantel locations for wood burning fireplaces. 
Hood (p/n 075629) must be installed when 
mantel is 12" from fireplace opening. 
Note: Glass doors must be removed when 
using hood.
W
ARNING
Figure 38 - Locating Mantel 12" from Opening 
when Using Hood  
Figure 39 - Placement of Combustible 
Mantel and Trim without Hood 
Top Spacers
Note: No 
combustible 
materials 
within 12" 
of opening. 
2¾" Hood
(p/n 075629) 
Non-combustible 
Wall Board 
Shaded 
Area