Regency P48 Zero Clearance Direct Vent Gas Fireplace
17
INSTALLATION
Vertical Venting with Three (3) 90
o
 Elbows
Option        V
H + H1
V + V1
     A)
2' Min.
3' Max.
4' Min.
     B)
3' Min.
4' Max.
6' Min.
     C)
4' Min.
5' Max.
7' Min.
     D)
5' Min.
6' Max.
8' Min.
     E)
6' Min.
7' Max.
9' Min.
     F)
7' Min.
8' Max.
10' Min.
With these options, max. to-
tal pipe length is 30 feet with
min. of 10 feet total vertical
and max. 8 feet total horizon-
tal.
Please note min. 1 foot
between 90
o
 elbows is re-
quired.
Vertical Venting with Three (3) 90
o
 Elbows
            Option
     H
    V
H + H1    V + V1
A)
1' Max.
1' Min.
3' Max.
3' Min.
B)
2' Max.
2' Min.
4' Max.
5' Min.
C)
3' Max.
3' Min.'
5' Max.
7' Min.
D)
4' Max.
4' Min.
6' Max.
9' Min.
E)
5' Max.
5' Min.
7' Max.
11'  Min.
With these options, max. total
pipe length is 30 feet with min.
of 11 feet total vertical and
max. 7 feet total horizontal.
Please note min. 1 foot
between 90
o
 elbows is re-
quired.
One 90
o
 elbow = Two 45
o
 elbows.
One 90
o
 elbow = Two 45
o