Regency L900-LP ユーザーズマニュアル

ページ / 56
Regency
®
 L900 Direct Vent Gas Fireplace
45
MAINTENANCE
MAINTENANCE
6)  Cut the cable tie that is holds the wires 
connected to the control module.
7) Disconnect the 3 connectors from the 
control module.
8)  Pull out the control module.  
 
NOTE: The control module is held in place 
with velcro.
1)   Remove the exterior brick panels.
2)   Remove the glass door.
3)   Loosen the 2 screws that hold the left side  
heat shield in place.
4)   Lift up and pull out the heat shield slightly 
to clear the screwheads and then hang it 
on the top bracket (located directly above 
the heat shield).
Control Module
9)  Replace the control module
10) Reverse steps to re-install.
CONTROL MODULE REPLACEMENT
5) Unplug the power source.
 
a.  Release the 2 door latches on the left      
     and right side at the top of the fi rebox.
 b.  
 Swing the door out from the top and release   
the hinges on the left and right side of the  
door by lifting them up.
Hinge
Door
Latch
Latch Location
Heat 
Shield
Bracket
Heat 
Shield
  c.    Place the door on a soft surface to prevent 
scratching.