Regency U35-NG1 ユーザーズマニュアル

ページ / 32
8
U35 FPI Direct Vent Gas Insert
MINIMUM CLEARANCES TO COMBUSTIBLES
From Unit 
           
Sides 
 
A  8" / 203 mm
Ceiling 
 
B  34" / 834 mm
From Standard Surround  31-1/8" x 44-1/8" (791mm x 1121mm)
Sides
 
 
D  1-15/16" / 49 mm
Ceiling 
 
E  28-7/8" / 733 mm
Max. Mantel Depth  12" / 305 mm
Min. Alcove Width  K  48" / 1220 mm
Max. Alcove Depth  L  36" / 915 mm
* No Hearth Required
REGENCY  BAY  &  FLUSH
COMBUSTIBLE  MANTEL  CLEARANCES
KENSINGTON  FRONT
COMBUSTIBLE  MANTEL  CLEARANCES
Mantel can be installed anywhere in shaded area or higher using the above scale.
Note:  Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.
Because of the extreme heat this insert emits, the mantel clearances are critical.
Combustible mantel clearances from top of unit are shown in the above diagrams.
Note:  A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible 
board.
INSTALLATION