Monessen Hearth NB24 ユーザーズマニュアル

ページ / 40
81D0107 
11
16"
42"
CLEARANCES 
AND
 HEIGHT REQUIREMENTS
Sidewall and ceiling clearances: 
The sides of the fireplace opening must be at least 16" from any combustible wall. 
The ceiling must be at least 42" from the top of the fireplace opening. 
Figure 4 - Sidewall and Ceiling Clearances
The dimensions shown in Figures 4 through 12 and defi ned in the fi replace manufacturer's 
instructions are minimum clearances to maintain when installing this heater. Left and 
right clearances are determined when facing the front of the heater.
When heater is installed into a ventless fi rebox, minimum clearances, as specifi ed by 
the ventless fi rebox manufacturer, must be met.
Follow these instructions carefully to ensure safe installation. Failure to follow 
instructions exactly can create a fi re hazard.
W
ARNING