CAUTION
Template for kiva-style arch represents MINIMUM inside 
dimensions. When constructing kiva-style arch, you must 
add thickness of fi nishing materials to achieve proper size 
of fi nished arch.
CAUTION
NOTE: Previous numbers are for combustible 
construction numbers. Arch may protrude up to 
5-1/2 inches maximum as measured from unit 
front face.
NOTE: The kiva-style arch depth may be any size if 
using noncombustible materials i.e. concrete, steel, 
plaster, etc.
•  A template is provided on unit shipping carton. 
Simply cut along the line and use as a template when 
constructing kiva-style arch (see Figure 11.6).
 
BACKING
MATERIAL
KIVA-STYLE ARCH
STRUCTURE
FINISHING
MATERIAL
Figure 11.6
•   Inside of the kiva-style arch can be fi nished using com-
bustible materials. For example, thin drywall may be 
layered to form around curved arch.
OPTION C:   SOUTHWESTERN kiva-style
The third installation option illustrated is a corner-installa-
tion with custom fi nishing. This option requires advanced 
fi nishing methods involving either combustible or non-com-
bustible construction materials (see Figure 11.7).
•   A template is provided on the unit shipping carton. 
Simply cut along the line and use as a template for 
construction purposes.
•  The cardboard template provided represents MINIMUM 
inside dimensions of the fi nished wall surface.
• If 
fi nishing with plaster or drywall, a fi nish edge trim is 
provided around door front on unit. Finishing materials 
MUST not extend inside of the fi nish edge trim.
Figure 11.7
WARNING
Fire Risk. 
Follow minimum specifi ed clearances found in 
Section 16, (Appliance Dimensions Diagram) 
and on fi replace exterior if using combustible 
framing materials.
Finishing materials cut inside the provided template or inside 