Before operating this heater, please review the safety warnings 
pages at the beginning of this manual and those precautions and 
warnings listed below.
1.  Know what type of ignition system this model has (standing 
pilot)  and  follow  the  applicable  SAFETY  and  LIGHTING 
instructions.
2.  Check to ensure there are no gas leaks. If you are unsure, turn gas 
off to the heater and call a service person or your gas utility.
CAUTION: Clothing or other flammable material should not 
be placed on or near the appliance.
WARNING: Children and adults should be alerted to the 
hazard of high surface temperature and should stay away 
to avoid burns or clothing ignition. Young children should 
be carefully supervised when they are in the same room as 
the appliance.
3.  Tampering  is  DANGEROUS  and  voids  all  warranties. Any 
component that is found to be faulty, must be replaced with an 
approved component.
Initial Lighting (Figure 14)
Upon completing the gas line or turning the gas valve "ON" after it 
has been in the "OFF" position, a small amount of air will be in the 
lines. When first lighting the appliance, it will take a few minutes 
for the lines to purge themselves of this air. Once the purging is 
complete, the appliance will light and operate satisfactorily.
Subsequent lightings of the appliance will not require such purging 
if the gas valve is not turned to "OFF."
Standing Pilot Operation
1.  Follow the SAFETY and LIGHTING INSTRUCTIONS for 
standing pilot controls found in this manual and on labels found 
attached to the appliance.
CAUTION: During the initial purging and subsequent lightings, 
never allow the gas valve control knob to remain depressed in 
the "pilot" position without pushing the piezo ignitor button 
at least once every second. 
2.  D u r i n g   t h e 
heating  season, 
leave the control 
valve knob in the 
"ON"  position. 
This  will  allow 
the  pilot  flame 
to  remain  lit. 
Turn the burner 
flame  on  or  off  with  the 
appliance ON/OFF rocker 
switch, wall switch, remote control kits or 750 millivolt wall 
thermostat.
NOTE: The gas control valve allows you to increase or decrease the 
height of the main burner flame. The control valve has a pressure 
regulator  with  a  knob  as  shown  in  Figure  14.  Rotate  the  knob 
clockwise to "HI" to increase the flame height and counterclockwise 
to "LO" to decrease the flame height.
3.  When the heating season is over, turn the on/off switch to "OFF" 
and the control valve to "OFF". The system, including the pilot 
light, will be shut down. 
 
Maximum and Minimum Input
The gas valve on the appliance allows the input to adjust between 
a maximum input of 30,000 to a minimum input of 21,000 Btuh. 
Please be advised, the maximum input provides the greatest amount 
of yellow flame and ember glow on the log set. The minimum 
input substantially decreases the yellow flame and ember glow 
on the log set.
LOG PLACEMENT
  1.  Remove screen front from inner body by removing (2) 10 x 
1/2" screws.
  2.  Remove logs from interior of firebox. Remove all protective 
packaging from logs and interior of firebox.
  3.  Place front log onto two (2) front pins on inner bottom.
  4.  Place rear log onto two (2) rear pins on rear log support.
  5.  Place top log onto two (2) pins on rear log.
  6.  Replace and attach screen front onto inner body with (2) 10 x 
1/2" screws from Step 1.
  7.  Log placement  is  completed.
Refer to Figure 13 for the following warning.
Warning: Failure to position the parts in accordance with this 
diagram or failure to use only parts specifically approved with this 
appliance may result in property damage or personal injury.
OPERATING GUIDELINES
Figure 13
Figure 14