16938-3-0806
MAIN BURNER FLAME CHARACTERISTICS
Figure 18 shows a correct main burner flame pattern.  Figure 19  
shows an incorrect main burner flame pattern.  
If main burner flame pattern is incorrect, as shown in Figure 19
•  See Troubleshooting, pages 20-21.
Correct Main Burner Flame
Figure 18
Incorrect Main Burner Flame
Figure 19
Cleaning and Maintenance / Main Burner
Warning: Turn off heater and let cool before cleaning
After use, cleaning of the main burner may be required for the 
proper flame. The main burner may be cleaned by applying air 
pressure to the ports on the main burner.
Cleaning the Log Set and Firebox
During the annual inspection and maintenance appointment, the 
service person should clean dust, lint, and any light accumulation 
from the logs and the firebox area. An extra-soft brush should be 
used on the logs as they are extremely fragile; a vacuum cleaner 
may be used on the firebox. If at any time the logs cannot be 
removed or installed without forcing, the cause must be found. 
The logs must never be forced.
CAUTION:  The ceramic logs are durable when handled and 
installed properly. However, they are delicate and may be damaged 
easily if not handled with care. Handling damage to the ceramic 
logs is not covered by warranty.
DO NOT HANDLE LOGS WHILE THEY ARE HOT. ALLOW 
PLENTY OF TIME FOR THE APPLIANCE TO COOL COM-
PLETELY BEFORE HANDLING.
PLEASE NOTE
It is normal for appliances fabricated of steel to give off 
some expansion and/or contraction noised during the start 
up or cool down cycle. Similar noises are found with your 
furnace heat exchanger or car engine.