Installing Optional CIB-2 Blower
  1.  Loosen, but do not remove, (4) hex-head screws located on 
the exterior, bottom of the appliance.
  2.  Position the blower assembly at the rear of the appliance. 
The blower assembly has (4) keyholes for attachment to the 
exterior, bottom of the appliance.
  3.  Place the large diameter holes in the keyholes over and behind 
the (4) hex-head screws that were loosened in Step 1. Push 
inward  on  the  blower  assembly  to  lock  the  keyholes  into 
position behind the screws. Tighten (4) hex-head screws to 
secure blower assembly to exterior, bottom of the appliance. 
(Refer to Figure 1)
  4.  Remove wire channel from rear cover by removing (4) hex-
head screws. Note: If optional blower is being installed during 
initial installation of appliance, the wire channel will not be 
attached to rear cover. (Refer to Wire Channel Installation, 
Page 13)
  5.  Remove casting top and casting front from casting.
  6.  If optional stone inlay is installed in casting top, remove the 
12" x 19 3/8" heat shield from the heat exchanger top by 
removing (4) 1/2" hex-head screws.
  7.  When facing the rear of the appliance, insert fan control shield 
between rear cover and inner body of appliance on the left 
side of the rear cover.
  8.  Attach fan control shield to top of inner body with (2) #10 x 
1/2" screw provided in hardware package.  (Refer to Figure 
2)
  9.  If applicable, attach 12" x 19 3/8" heat shield to heat exchanger 
top with (4) 1/2" hex-head screws from Step 6.
 10.  Place the casing top onto the casting. The casting top nests 
into the casting.
  11.  Attach fan control to FLAT, fan control bracket (Part 9A, Page 
26) with (2) 6 x 1/4" screws provided in hardware package.
 12.  Attach fan control with bracket onto the wire channel by using 
(2) 8 x 1/4" screws provided in hardware package.
 13.  Route wires from fan control and ON/OFF/REMOTE switch 
within wire channel.
 14.  When facing the rear of the appliance, align and insert fan 
control with bracket into 1 3/8" x 2" opening on the left side 
of the rear cover.
 15.  Attach wire channel to rear cover by using (4) hex-head screws  
removed in Step 4. (Refer to Wire Channel Installation
Page 13)
 16.  Insert AUTO/OFF/ON switch into rectangular notch on valve 
bracket. Be sure to insert AUTO/OFF/ON switch with letters 
(words) upright. (See wiring diagram)
 17.  Attach 1/4" push-on terminal from blue wire on the fan control 
to the AUTO (top) tab on the switch.
 18.  Attach 1/4" push-on terminal from black wire to the OFF 
(middle) tab on the switch.
 19.  Attach  1/4"  push-on  terminal  from  white  wire  on  the  fan 
control to the ON (bottom) tab on the switch.
 20.  Installation of optional CIB-2 blower is completed.
Fan Control
The fan control is a non-adjustable automatic type.  The fan control 
will require between 5 and 10 minutes of main burner operation 
before the fan control "closes" and activates the blower.  The blower 
will  continue  to  run  between  5  and  10  minutes  after  the  main 
burner shuts off, before the fan control "opens" and deactivates 
the blower.
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS
Figure 1
Figure 2