Lennox Hearth EBVI30 ユーザーズマニュアル

ページ / 20
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
2
 It is imperative that the control compart-
ment, burners and circulating air passage 
ways of the appliance be kept clean.
S'assurer que le brùleur et le compartiment 
des commandes sont propres.  Voir les 
instructions d'installation et d'utilisation 
qui accompagnent l'appareil.
GENERAL INFORMATION
Installation, repair and annual service in-
spection should be performed by a qualifi ed 
service technician. 
Provide adequate clearances around air openings 
and adequate accessibility clearance for service 
and proper operation.
Never obstruct the front openings of the 
appliance.
Due to high temperatures of this appliance 
adequate clearances need to be maintained from 
furniture and draperies and other combustibles.  
Locate furniture and window coverings accord-
ingly. 
The recommended clearance zone from 
the front of the appliance to combustibles is 36 
inches (914 mm)
. Maintain all other clearances 
as outlined in the Installation Manual. 
These fi replaces are designed as supplemen-
tal heaters. Therefore, it is advisable to have 
an alternate heat source when installed in a 
dwelling.
Input of millivolt model is variable. The rates 
are shown in the following table:
This appliance complies with National 
Safety Standards and is tested and listed 
by OMNI-Test Laboratories Inc.; Beaverton, 
Oregon (Report No. 116-F-15-5) to ANSI 
Z21.88-2002 (in Canada, CSA-2.33-2002), 
and CAN/CGA-2.17-M91 in both USA and 
Canada, as vented gas heaters. 
Installation must conform to local codes. In 
the absence of local codes, installation must 
comply with the current National Fuel Gas 
Code, ANSI Z223.1. (In Canada, the current 
CAN-1 B149 installation code.)  Electrical 
wiring must comply with the National Elec-
trical Code ANSI/ NFPA 70 - latest edition.  
In Canada, the current CSA C22-1 Canadian 
Electrical Code - latest edition.
TABLE OF CONTENTS
Introduction ......................................Page  2
General Information ..........................Page  2
Burn-In Period ..................................Page  3
Lighting Millivolt Appliances .............Page  3
Gas Controls .....................................Page  3
Control Compartment Access ...........Page  4
Operation & Care of Your Appliance ..Page  4
Maintenance Procedures ...................Page  4
Maintenance Schedule ......................Page  6
Front Glass Door Assembly,
  Removal and Installation .................Page  7
Burner Adjustments ..........................Page  7
Flame Appearance and Sooting .........Page  7
Log Placement Instructions ..............Page  8
Millivolt Appliance Checkout .............Page  11
Blower Operation ..............................Page  11
Fireplace Requirements .....................Page  11
Wiring Diagrams ...............................Page  11
Warranty Information ........................Page  12
Accessory Components ....................Page  12
Lighting Instructions – Millivolt ........Page  15
Replacement Parts List .....................Page  17
Troubleshooting Guide ......................Page  19
INTRODUCTION
The Insert model covered in this manual is 
a B-Vent gas heater designed for residential 
application for installation into an existing 
masonry or factory built solid-fuel fi replace 
using 4" diameter, UL1777 listed aluminum 
liner  for the exhaust. The vent must be routed 
through the existing fi replace fl ue system to the 
vent termination.
This millavolt appliance is designed to operate 
on either natural or propane gas.
 A millivolt 
gas control valve with piezo ignition system 
provides safe, effi cient operation.  External 
electrical power is required to operate the air 
circulation blower.  
Millivolt  Models with
MAnnually-Modulated Gas Valves
Nat. Gas
Propane
Model No.
Input Rate
(BTU/HR)
Input Rate
(BTU/HR)
EBVI25
17,000 to 
25,000
19,500 to
25,000
EBVI30
21,500 to 
30,000
22,000 to
28,000
Table 1
       WARNING 
Do not attempt to alter or modify 
the construction of the appliance 
or its components. Any modi-
fi cation or alteration may void 
the warranty, certifi cation and 
listings of this unit.
       WARNING 
Improper installation, adjust-
ment, alteration, service or 
maintenance can cause injury 
or property damage.  Refer to 
this manual.  For assistance or 
additional information consult 
a qualifi ed installer, service 
agency or the gas supplier.
       WARNING 
These fireplace Inserts are 
vented heaters.  Do not burn 
wood or other material in these 
appliances.
CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANU-
FACTURED BY LENNOX HEARTH PRODUCTS.
 
When you purchased your new gas-fi red heater, you joined the ranks of thousands of 
individuals whose answer to their home heating needs refl ects their concern for effi ciency 
and our environment. We extend our continued support to help you achieve the maximum 
benefi t and enjoyment available from your new gas-fi red heater. It is our goal at Lennox 
Hearth Products to provide you, our valued customer, with an appliance that will ensure 
years of trouble-free warmth and pleasure. 
 
Thank you for selecting a Lennox Hearth Products gas-fi red heater as the answer to 
your home heating needs.
Sincerely, 
All of us at Lennox Hearth Products