Pellets or Corn/Pellet Mixture Only                                           3-90-775                                                                           Save These Instructions
                         P35i Fireplace Insert
C.  Venting Requirements and 
Restrictions
A combustion blower is used to extract the combus-
tion gases from the firebox. This causes a negative pres-
sure in the firebox and a positive pressure in the venting 
system. The longer the vent pipe and more elbows used 
in the system, the greater the flow resistance.
 
The  recommended  maximum  flue  lengths  for  the 
P35i Insert are as follows:
3" or 4" Stainless Steel Flex:
 30 Lineal ft. Vertical*
4" PL Vent Pipe:
4" Pl Vent Pipe: 30 Lineal ft. Vertical*
4" Pl Vent Pipe: 14 ft. Vertical w/1-90
o
 and 12 lineal ft. 
horizontal*
If  additional  4"  PL  Vent  fittings  are  required,  the 
overall length must be reduced by:
Vertical 90
o
 or T:  
2.5'
Vertical 45
o
:   
1.5'
Horizontal 90
o
 or T:   5.0'
Horizontal 45
o
:  
2.5'
3" PL Vent Pipe:
20 Lineal ft. vertical*
8 Lineal ft. vertical w/1-90
o
 & 8 lineal ft. horizontal*
If  additional  3"  PL  Vent  fittings  are  required,  the 
overall length must be reduced by:
Vertical 90
o
 or T:  
2.0'
Vertical 45
o
:   
1.0'
Horizontal 90
o
 or T:   4.0'
Horizontal 45
o
:  
2.0'
*  Long  runs  of  flex  or  PL  vent  pipe  installed  directly 
vertical from the flue stub may require more frequent 
cleaning due to fly ash falling off inside and collecting 
directly above the combustion blower outlet.
     Any  use  of  horizontal  venting  will  require  more 
frequent cleaning. It is the responsibility of the installer 
to make sure the entire flue configuration is accessible 
for cleaning.
Stainless  steel  flex  vent  is  only  allowed  for  use  in 
masonry fireplaces and chimneys or in factory built wood 
burning fireplace installations when used as a liner for 
a class A metal chimney. All pellet vent pipe must be 
secured together by means provided by pipe manufac-
turer. The vent pipe must be secured to the appliance 
flue collar with a minimum of three screws.
It is also recommended that you seal all vent pipe 
joints with high temperature silicone.
Use only the specified venting components. Use 
of  any  other  components  will  void  the  product 
warranty and may pose a hazard.
Do  Not  Install  A  Flue  Damper  In  The  Exhaust 
Venting System Of This Appliance.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE 
SERVING ANOTHER APPLIANCE. 
NOTE: If burning a shelled corn and pellet mixture, 
you must use approved venting components that 
are specifically designed for corn burning.
WARNING! RIsK Of fIRE!
•  Only LISTED type L or PL Pellet venting compo-
nents may be used.
•  NO OTHER type of venting materials or compo-
nents may be used.
•  Substitute or damaged vent components may 
impair safe operation.
WARNING! RIsK Of INJURy OR pROpERTy
DAmAGE!
•  Improper installation, adjustment, alteration, 
service, or maintenance can cause injury or 
property damage.
•  Read and Refer to your owner's manual.
•  For assistance or additional information, consult a 
qualified installer, service agency or your dealer.
IN CANADA: This fireplace insert must be 
installed with a continuous chimney liner of a 
minimum 3" diameter extending from the insert 
to the top of the chimney. The chimney liner must 
conform to the Class 3 requirements of CAN/ULC-
S635, Standard for Lining Systems for Existing 
Masonry or Factory Built Chimneys and Vents, or 
CAN/ULC-S640, Standard for Lining Systems for 
New Masonry Chimneys.