SPECIFICATIONS
Figure 47 - Remote Control Wiring Diagram
Black Connectors
Receiver
To Thermopile
White
Red
Model VSGF36NRC
•  Rating (Variable): 33,000/21,500 Btu/Hr
•  Type Gas: Natural Gas
•  Ignition: Electronic
•  Pressure Manifold: 3.5" W.C.
•  Inlet Gas Pressure (in. of water): 
  Maximum 10.5" W.C., Minimum* 5" W.C.
•  Shipping Weight: 
120 lbs.
* For input adjustment
Model VSGF36PRC
•  Rating (Variable): 33,000/21,500 Btu/Hr
•  Type Gas: Propane/LP
•  Ignition: Electronic
•  Pressure Manifold: 7.9" W.C.
•  Inlet  Gas  Pressure  (in.  of  water): 
Maximum 13" W.C. Minimum* 11" W.C.
•  Shipping Weight: 
120 lbs.
* For input adjustment
TECHNICAL SERVICE
You may have further questions about installa-
tion, operation or troubleshooting. If so, contact 
FMI  PRODUCTS,  LLC  at  1-866-328-4537. 
When  calling,  please  have  your  model  and 
serial numbers of your firebox ready.
You  can  also  visit  FMI  PRODUCTS,  LLC’s 
web site at 
www.fmiproducts.com.
SERVICE HINTS
When Gas Pressure Is Too Low
•  pilot will not stay lit
•  burners will have delayed ignition
•  heater will not produce specified heat
•  propane/LP  gas  supply  may  be  low  for 
propane/LP unit
You may feel your gas pressure is too low. If 
so, contact your local gas supplier.
WIRING DIAGRAM
Note: For proper operation of remote control, wires from thermopile to control receiver must 
be connected exactly as shown.