FIrePlACe INstAllAtIoN
Figure 12 - Removing Front Refractory 
Access Panel (P325E/VP325E Model 
Shown)
Figure 13 - Installing the WRC Remote 
Receiver
Fireplace 
Receptacle
Remote 
Control 
Receiver
Extension 
Cord
Ignition Module 
Plug
Figure 14 - Installing Battery into Back of 
Handset
Pull to Remove 
Insulation Tab
Battery Cover
12 Volt Battery
Back of 
Handset
WALL SWITCH INSTALLATION
The installation of a wall switch allows you 
to activate the gas control valve and turn the 
fireplace on and off. The wall switch is to be 
connected to the incoming 120 volt regular 
household wiring that supplies the electricity 
to  the  fireplace.  Refer  to  Wiring  Diagram
page 21.
OPTIONAL REMOTE CONTROL 
INSTALLATION (Model WRC)
Note:  If  using  optional  wireless  hand-held 
remote  control,  wall  switch  must  be  in  ON 
position to be operational. The remote control 
then becomes the switching mechanism for 
fireplace operation.
1.  Remove front refractory access panel by 
lifting up and angling out of firebox open-
ing (see Figure 12).
2.  WRC model receiver does not require a 
battery. Receiver can be installed by first 
plugging short extension cord into fireplace 
receptacle. Plug receiver unit into exten-
sion cord. Finally, plug ignition module plug 
into receiver unit (see Figure 13).
3.  Activate  remote  handset  battery  by  re-
moving insulating tab on back of handset 
(see Figure 14). Battery is included pre-
installed.
4.  Once battery is activated, unit is ready to 
use.
5.  Replace front refractory access panel.