WIRING DIAGRAM
Note: For proper operation of optional acces-
sories, the wires from the switch to the control 
must be connected exactly as shown.
AUTO
OFF
ON
Thermopile
SPECIFICATIONS
VYGF33NRC
•  Rating: 20,000/30,000 Btu/Hr
•  Gas Type: Natural Gas
•  Ignition: Piezo
•  Pressure Manifold: 3.5" W.C.
•  Inlet Gas Pressure (in. of water):
  Maximum - 10.5" W.C., Minimum* - 5" W.C.
•  Shipping Weight: 122 lbs.
* For input adjustment
VYGF33PRC
•  Rating: 20,000/33,000 Btu/Hr
•  Gas Type: Propane/LP Gas
•  Ignition: Piezo
•  Pressure Manifold: 8.0" W.C.
•  Inlet Gas Pressure (in. of water):
  Maximum - 14" W.C., Minimum* - 11" W.C.
•  Shipping Weight: 122 lbs.
* For input adjustment
REPLACEMENT PARTS
Note:  Use  only  original  replacement  parts. 
This will protect your warranty coverage for 
parts replaced under warranty.
pARTS UNDER WARRANTY
Contact authorized dealers of this product. If 
they can’t supply original replacement part(s), 
call  DESA  Heating,  LLC  at  1-866-672-6040. 
When  calling  DESA  Heating,  LLC,  have 
ready
•  your name and address
•  model and serial numbers of your fireplace
•  how fireplace was malfunctioning
•  type  of  gas  used  (propane/LP  or  natural 
gas)
•  purchase date
Usually, we will ask you to return the part to 
the factory.
pARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If 
they can’t supply original replacement part(s), 
call  DESA  Heating,  LLC  at  1-866-672-6040 
for  referral  information.  When  calling  DESA 
Heating, LLC, have ready
•  model number of your fireplace 
•  the replacement part number
TEChNICAL SERVICE
You may have further questions about instal-
lation, operation or troubleshooting. If so, con-
tact DESA Heating, LLC at 1-866-672-6040. 
When  calling,  please  have  your  model  and 
serial numbers of your heater ready.
You can also visit DESA Heating, LLC’s  web 
site at www.desatech.com.
SERVICE hINTS
When Gas pressure Is Too Low
•  pilot will not stay lit
•  burner will have delayed ignition
•  fireplace will not produce specified heat
•  for propane/LP unit, propane/LP gas supply 
may be low 
You may feel your gas pressure is too low. If 
so, contact your local gas supplier.