Determining if You Have a Confined or 
unconfined space
Use this work sheet to determine if you have 
a confined or unconfined space.
space: Includes the room in which you will 
install heater plus any adjoining rooms with 
doorless  passageways  or  ventilation  grills 
between the rooms.
1.  Determine the volume of the space (length 
x width x height).
 
Length x Width x Height = ______cu.  ft. 
(volume of space)
 
Example: Space size 22 ft. (length) x 18 
ft. (width) x 8 ft. (ceiling height) = 3168 cu. 
ft. (volume of space)
 
If additional ventilation to adjoining room 
is supplied with grills or openings, add the 
volume of these rooms to the total volume 
of the space. 
2.  Multiply the space volume by 20 to deter-
mine the maximum Btu/Hr the space can 
support.
 
  _____ (volume of space) x 20 = (Maxi-
mum Btu/Hr the space can support)
 
Example: 3168 cu. ft. (volume of space) x 
20 = 63,360 (maximum Btu/Hr the space 
can support)
3.  Add the Btu/Hr of all fuel burning appli-
ances in the space.
 
Vent-free heater 
 _______ Btu/Hr
 
Gas water heater* 
 _______ Btu/Hr
 
Gas furnace 
 _______ Btu/Hr
 
Vented gas heater 
 _______ Btu/Hr
 
Gas fireplace logs 
 _______ Btu/Hr
 
Other gas appliances* +  ______ Btu/Hr
 
Total 
= ______ Btu/Hr
 
*  Do  not  include  direct-vent  gas  appli-
ances.  Direct-vent  draws  combustion 
air  from  the  outdoors  and  vents  to  the 
outdoors.
 
Example:
 
Gas water heater 
 _________ Btu/Hr
 
Vent-free heater 
+ ________ Btu/Hr
 
Total 
= ________ Btu/Hr
AIR FOR COMBUSTION AND VENTILATION
Continued
4.  Compare the maximum Btu/Hr the space 
can  support  with  the  actual  amount  of 
Btu/Hr used.
 
  _________ Btu/Hr (maximum the space 
can support) 
 
  _________ Btu/Hr (actual amount of 
 
 
Btu/Hr used)
 
Example:  63,360  Btu/Hr  (maximum  the 
space can support) 
 
 
79,000 Btu/Hr (actual amount 
of Btu/Hr used)
The space in the above example is a confined 
space because the actual Btu/Hr used is more 
than the maximum Btu/Hr the space can sup-
port.  You  must  provide  additional  fresh  air. 
Your options are as follows:
A.  Rework  worksheet,  adding  the  space 
of an adjoining room. If the extra space 
provides  an  unconfined  space,  remove 
door to adjoining room or add ventilation 
grills between rooms. See Ventilation Air 
From Inside Building
, page 7.
B.  Vent room directly to the outdoors. See 
Ventilation Air From Outdoors, page 7.
C.  Install  a  lower  Btu/Hr  heater,  if  lower 
Btu/Hr size makes room unconfined. 
If  the  actual  Btu/Hr  used  is  less  than  the 
maximum Btu/Hr the space can support, the 
space is an unconfined space. You will need 
no additional fresh air ventilation. 
 WARNING: If the area in which 
the heater may be operated does 
not meet the required volume for 
indoor combustion air, combus-
tion and ventilation air shall be 
provided by one of the methods 
described  in  the  National  Fuel 
Gas Code, ANSI Z223.1/NFPA 54, 
the International Fuel Gas Code, 
or applicable local codes.
40,000
39,000
79,000