FireplaceXtrordinair 36CF ユーザーズマニュアル

ページ / 48
20
Installation  
(for qualified installers only)
© Travis Industries
4090102
100-01212_000
Vent Clearances
IN THE ENCLOSURE (under 78") 
Vertical or Horizontal Sections:
6" Clearance Above
3-1/2" Clearance To The Side
2" Clearance Below
Horizontal Penetrations
(through walls, etc.)
(thimble is required  - sku 98900030) 
4" Clearance Above
2" Clearance To The Side
2" Clearance Below
Vertical Penetrations 
(through ceilings, roofs, etc.)
(firestop is required - sku 98900029)
1" Clearance To the Side
ABOVE THE ENCLOSURE (over 78") 
Vertical Sections:
1" Clearance To the Side
Horizontal Sections:
4" Clearance Above
2" Clearance To The Side
2" Clearance Below
Vent Location
The starter section is set at a 45
°
 angle.  Place a 45
°
 elbow directly on top of the fireplace and route it
vertically or horizontally.  The approximate position of the vent is shown below.
41-3/4"
1"
Framing to the rear of the fireplace.
46"
3-1/2"
Framing to the rear of the fireplace.
TOP VENT
REAR VENT
NOTE: In cases where the vent is routed vertically 
directly above the fireplace, you may place a 90° 
elbow directly on top of the fireplace, followed by a 
45° elbow that directs the vent upwards.  For vent 
configuration purposes this is considered a top vent 
and the 90° and 45° elbow is considered a single 
45° elbow.
56"
9-1/4"