Desa BC165CT ユーザーズマニュアル

ページ / 52
www.desatech.com
15
111168-01A
IGNITION CONTROL ASSEMBLY
 WARNING: High Voltage!
1.  Unplug heater.
2.  Remove side cover screws (4) using 5/16" 
nut-driver to expose ignition control assembly 
(see Figure 15 or 16, page 11).
3.  Remove fuse cover (see Figure 29).
4.   Remove fuse from fuse clips (see Figure 29).
5.  Replace fuse with fuse of the same type and 
rating (GMA-10). Do not substitute a fuse 
with a higher current rating.
Figure 29 - Replacing Fuse
Fuse 
Fuse 
Cover
Fuse 
Clips
6.   Replace fuse cover (see Figure 29).
7.  Replace side cover (see Figure 15 or 16, page 11).
Power Plug
120V/60Hz
Blue
Blue
White
White
Photocell
Ignition Control Assembly
Green
  
Green
Red
Black
Black
 Yellow
Ye
llo
w
Motor
Ignitor
Thermostat
Photocell
Photocell
Ignitor
Motor Return
AC Neutral (L2)
120V (L1)
Ignitor
Motor
Figure 31 - Wiring Diagram for 55T/70T/115T/165T Thermostat Models
Power Plug
120V/60Hz
Blue
Blue
White
White 
Photocell 
Green
Green
Red
Black 
Yel low
Ye
ll
ow
Motor
Ignitor
Ignition Control Assembly
 
Photocell
Photocell
Ignitor
Motor Return
AC Neutral (L2)
120V (L1)
Ignitor
Motor
Figure 30 - Wiring Diagram for 40 Models
WIRING DIAGRAMS 
SERVICE PROCEDURES
Continued