VENTILATION 
 WARNING: Provide a fresh air 
opening of at least three square 
feet (2,800 square cm) for each 
100,000  Btu/Hr  rating.  Provide 
extra  fresh  air  if  more  heaters 
are  being  used.  The  minimum 
ventilation  requirements  must 
be  followed  to  avoid  risks  as-
sociated with carbon monoxide 
poisoning.  Make  certain  these 
requirements  are  met  prior  to 
operating heater.
Example:
 A 165 model heater requires one of 
the following:
•  a two-car garage door (16 ft. [4.88 m] wide 
opening) raised four inches (10.16 cm)
•  a single-car garage door (9 ft. [2.74 m] wide 
opening) raised seven inches (17.78 cm)
•  two, thirty-inch (76.20 cm) windows raised 
twelve inches (30.48 cm)
OPERATION 
IMPORTANT: Review and under-
stand the warnings in the Safety 
Information  section,  page  2. 
They are needed to safely oper-
ate this heater. Follow all local 
ordinances  and  codes  when 
using this heater.
TO START HEATER
1.  Follow  all  ventilation  and  safety  informa-
tion.
2.  Fill fuel tank with kerosene, #1/#2 diesel/fuel 
oil, JET A or JP-8 fuels.
3.  Attach fuel cap.
4.  For thermostat models 55T, 70T, 115T, and 
165T, turn thermostat knob clockwise to the 
high position.
5.  Plug  heaterʼs  power  cord  into  approved, 
grounded, three-wire extension cord. Extension 
cord must be at least six feet (1.8 meters) long.
 
Extension Cord Size Requirement
 
6 to 10 feet (1.8 to 3 meters) long, use 18 AWG 
(0.75 mm2) rated cord
 
11 to 100 feet (3.3 to 30.5 meters) long, use 
16 AWG (1.0 mm2) rated cord
 
101 to 200 feet (30.8 to 61 meters) long, use 
14 AWG (1.5 mm2) rated cord
6.  Plug extension cord into standard 120 volt/60 
hertz, 3-prong grounded outlet. Note: Ignitor will 
preheat for five seconds, then heater will start.
7.  For thermostat models 55T, 70T, 115T, and 
165T, adjust thermostat knob to the desired 
setting.  Note: A  cold  heater  may  affect 
the thermostat setting. This thermostat is a 
general-heating control. It is not intended for 
precise temperature control. Adjust thermostat 
until heater cycles at the desired setting.
TO STOP HEATER
Unplug extension cord from outlet.
TO RESTART HEATER
1.  Unplug extension cord from outlet and wait 
10 seconds. (Wait two minutes if heater has 
been running.)
2.  Repeat steps under To Start Heater.