11 Device Information
1
Type and order code 
LI 11TER+
LI 16TER+
2
Design
2.1
Model
Reversible
Reversible
2.2
Degree of protection according to EN 60 529 for compact devices
and heating components
 IP 21
 IP 21
2.3
Installation Location
Indoors
Indoors
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow 
1
°C / °C
1. See operating limits diagram 
Up to 58 / above 18
Up to 58 / above 18
Cooling, flow
°C
+7 to +20
+7 to +20
Air (heating)
°C
-25 to +35
-25 to +35
Air (cooling)
°C
+15 to +40
+15 to +40
3.2
Temperature spread of heating water at A7 / W35
9.7
5.0
.9..3
5..0
3.3
Heat output / COP 
at A-7 / W35
2
kW / ---
2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature
and 55 °C heating water flow temperature.
7.1 / 2.9
6.6 / 2.7
10.6 / 3.0
10.5 / 2.9
at A-7 / W45
2
kW / ---
6.4 / 2.3
9.9 / 2.5
at A2 / W35 
2
kW / ---
8.8 / 3.2
8.8 / 3.1
12.8 / 3.4
12.7 / 3.2
at A7 / W35 
2
kW / ---
11.3 / 3.8
11.3 / 3.6
15.1 / 3.8
14.9 / 3.6
at A7 / W45 
2
kW / ---
9.6 / 3.1
14.7 / 3.3
at A10 / W35 
2
kW / ---
12.2 / 4.1
12.1 / 3.9
16.7 / 4.1
16.6 / 3.9
3.4
Temperature spread of cooling water at A35 / W7
6.5
5.0
6.6
5.0
3.5
Cooling capacity / COP
at A27 / W7
kW / ---
8.8 / 2.8
8.8 / 2.8
12.6 / 2.6
12.5 / 2.6
at A27 / W18
kW / ---
10.9 / 3.3
10.8 / 3.2
16.4 / 2.8
16.4 / 2.8
at A35 / W7
kW / ---
7.6 / 2.1
7.5 / 2.1
10.7 / 2.0
10.6 / 2.0
at A35 / W18
kW / ---
9.5 / 2.5
9.5 / 2.5
14.3 / 2.3
14.3 / 2.2
3.6
Sound power level
dB(A)
55 / 61
57 / 62
3.7
Sound pressure level at a distance of 1 m (indoors)
dB(A)
50
52
3.8
Heating water flow with an internal pressure differential of m³/h / Pa
1.0 / 3000
1.9 / 10900
1.4 / 4500
2.6 / 14600
3.9
Cooling water flow with an internal pressure differential of m³/h / Pa
1.0 / 3000
1.3 / 5900
1.4 / 4500
1.8 / 7000
3.10 Air flow rate with an external static pressure differentia
m³/h / Pa
4200 / 0
5200 / 0
m³/h / Pa
2500 / 25
4000 / 25
3.11 Refrigerant; total filling weight
type / kg
R404A / 5.1
R404A / 5.7
4
Dimensions, connections and weight
4.1
Device dimensions 
H x W x L cm
136 x 75 x 88
157 x 75 x 88
4.2
Device connections to heating system
Inch
G 1 1/4'' external
G 1 1/4'' external
4.3
Device connections to additional heat exchanger
(waste heat recovery)
Inch
G 1 1/4'' external
G 1 1/4'' external
4.4
Air duct inlet and outlet (min. internal dimensions)
L x W cm
50 x 50
57 x 57
4.5
Weight of the transportable unit(s) incl. packing
kg
222
260
5
Electrical connection
5.1
Nominal voltage; fuse protection
V / A
400 / 16
400 / 20
5.2
Nominal power consumption 
2
A2 W35
kW
2.74
2.86
3.8
4.0
5.3
Starting current with soft starter
A
23
25
5.4
Nominal current A2 W35 / cos 
ϕ
A / ---
4.9 / 0.8
5.16 / 0.8
6.9 / 0.8
7.2 / 0.8
6
Complies with the European safety regulations
3
3. See CE declaration of conformity
3
7
Additional model features
7.1
Defrosting
Automatic
Automatic
Type of defrosting
Reverse cycle
Reverse cycle
Defrosting tray included 
Yes (heated)
Yes (heated)
7.2
Heating water in device protected against freezing
Yes
4
4. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes
4
7.3
Performance levels
1
1
7.4
Controller internal/external
Internal
Internal