2.  Removing the electronic control P.C. board, the
power monitor receiver P.C. board, SW P.C. board
and the terminal block
(1) Remove the horizontal vane, the panel (Refer to 1.) and 
the corner box.  
(2) Remove the screw of the conduit cover, and conduit cover. 
(See Photo 2. or Photo 3.)
(3) Remove the indoor/outdoor connecting wire.
(4) Remove the switch holder from the electrical cover. 
(See Photo 4.)
(5) Remove the screw of the electrical cover, and then the 
electrical cover. (See Photo 4.)
(6) Remove the ground wire connected to the indoor 
electronic control P.C. board from the electrical box. 
(See Photo 5.)
(7) Unhook the power monitor receiver P.C. board holder from 
the catch. (See Photo 4.)
(8) Open the rear cover of the power monitor receiver P.C. 
board holder and pull out the power monitor receiver P.C. 
board. 
(9) Open the switch holder and pull out SW P.C. board.
(10) Pull the electronic control P.C. board slightly toward you 
from the electrical box, and disconnect TAB3 and all the 
connectors on the electronic control P.C. board. 
(LD101 and LD105 are direct-mounted to the electronic 
control P.C. board.)
(11) Pull out the electronic control P.C. board from the electrical 
box.
(12) Remove the ground wire connected to the heat exchanger
from the electrical box. (See Photo 5.)
(13) Unhook the catches of the electrical box, and pull out the 
electrical box.
(14) Remove the screw of the terminal block cover, and then
remove the terminal block cover and the terminal block 
holder. (See Photo 6) 
(15) Remove the terminal block by sliding it. 
OPERATING PROCEDURE
PHOTOS
Screw of the 
electrical cover.
Switch holder
Photo 4
3. Removing the electrical box
(1) Remove the horizontal vane, the panel (Refer to 1.) and 
the corner box.    
(2) Remove the screw of Conduit cover, and then the indoor/
outdoor connecting wire. (See Photo 2. or Photo 3.)
(3) Remove the switch holder and the electrical cover.
(See Photo 4.)
(4) Remove the ground wire connected to the heat exchanger
from the electrical box. (See Photo 5.)
(5) Disconnect the following connectors on the electronic 
control P.C. board; the fan motor connector <CN211>, the 
indoor coil thermistor connector <CN112>, the vane motor 
connector <CN151>. (See Photo 5.)
(6) Unhook the catches of the electrical box, and pull out the 
electrical box.
Photo 5
Indoor coil thermistor
connector (CN112)
Indoor fan motor 
connector (CN211)
Vane motor 
connector (CN151)
Ground wire
Photo 6
Screw
Power monitor
receiver
P.C. board holder