PAGE 8 
INSTALLATION REQUIREMENTS
ELECTRICAL REQUIREMENTS cont.
POWER SUPPLY CORD 
(See Fig.1)
Wiring Requirements
For model ESA415M  
 
 
• 115-volt (103.5 minimum to 126.5 maximum) 
• 15-amp time-delay grounded fuse or circuit breaker 
• Use on single outlet circuit only.
For model ESA418M 
• 230/208 volt (187 min. to 253 max.)
• 15-amp time-delay fuse or circuit breaker
• Use on single outlet circuit only.
For model ESA424K 
• 230/208 volt (187 minimum to 253 maximum) 
• 20-amp time-delay grounded fuse or circuit breaker 
• Use on single outlet circuit only.
RECOMMENDED GROUNDING METHOD 
(See Fig.1)
This air conditioner must be grounded. This air conditioner is equipped with a power supply 
cord that has a 3 prong grounding plug. The power supply cord must be plugged into a mating, 
grounded 3 prong outlet, and grounded in accordance with all local codes and ordinances. If a 
mating outlet is not available, it is the customer’s responsibility to contact a qualified electrician 
and ensure that a properly grounded 3 prong outlet is installed.
POWER SUPPLY CORD 
(See Fig.2)
NOTE:  Your air conditioner's plug may differ slightly in appearance 
from the one shown.
A.  Reset button
B.  Test button
This room air conditioner is equipped with an a leakage current detection interrupter (LCDI) 
power supply cord required by UL. This power supply cord contains a current detection device. 
If the power supply cord is crushed, this device will detect current leakage and power will be 
disconnected from the air conditioner. If this power supply cord is damaged, it cannot be 
repaired and must be replaced with a cord from the product manufacturer. If the power supply 
cord is damaged call Haier Customer Service: 1-877-337-3639.
RESET
TEST
A
B
Fig. 2
Fig. 1
ESA415M
ESA418M
ESA424K
ESA415
ESA418
ESA424
115V
15 Amp
230V
15 Amp
230V
20 Amp
ESA415
ESA418
ESA424
115V
15 Amp
230V
15 Amp
230V
20 Amp
ESA415
ESA418
ESA424
115V
15 Amp
230V
15 Amp
230V
20 Amp