Indoor unit
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
   qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). 
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
5
5.Easily-demount cleaning of indoor unit
1.Top inlet can be taken down
Open the inlet grille, press the claw of the clip on the unit,then
take down the top inlet.(according to figure 1)
2.Horizontal flap can be taken down
Overturn the horizontal flap, press the claw of the clip ,then take
down horizontal flap.(according to figure 2)
3. Vertical louvers can be taken down
After taking down horizontal flap.vertical louvers are appeared,
draw the middle louver,and take down the horizontal louvers .
(according to figure 3)
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring
       is not correct, proper operation can not be carried out and will cause defect.
5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance
    between its two contacts should be not less than 3mm.
claw of the clip
 Figure 1
 Figure 2
Daff
 Figure 3
Indoor unit
Outdoor unit
Connecting wiring:
3G1.0mm
2
-mod 12:
3G1.5mm
2
-mod 18:
Power cable:
3G1.0mm
2
-mod 12:
3G1.5mm
2
-mod 18: