4.
Run power supply cable through the connector, leaving about 8” of 
wire inside the box.
5.
Connect the supply cable ground wire to green ground screw provided.
NOTE:  Lead holes for a #8 sheet metal screw have been provided in the
sides of the back box..  After the finished wall or ceiling has been put up,
drive  a  #  8(m4)  sheet  metal  screw  (recommended  1”  long)  through  the
side  of  the  box  not  mounted  to  the  stud. This  will  prevent  the  back  box
from pulling out when installing the heater assembly. (See Figure 1)
INSTALLATION OF BACK BOX 
IN EXISTING CONSTRUCTION
(WALL OR CEILING)
1.
Carefully mark and cut a hole measuring 9-3/8"  (235mm) wide by 11-
1/8"  (283mm)  long.    One  edge  of  the  hole  must  be  cut  along  the
edge of a stud.
2.
Proceed  to  No.  1  through  5  (Installation  of  Wall  Box  in  New
Construction).
FIELD CONVERSION FOR LOWER WATTAGE RATING
NOTE:  Refer to specification chart for lower wattage ratings which are 
available.
To convert heater to lower wattage rating, completely remove red jumper 
wire from both heating elements (See Figure 2).  Discard this jumper.  Be 
sure remaining wires are securely connected.
INSTALLATION AND WIRING 
OF HEATER / FAN ASSEMBLY
1.
Following wiring diagram (Figure 3) connect supply wiring to heater
leadwires in back box.
NOTE:  For 120 and 277 volt heaters connect the white neutral supply 
lead to the heaters white pigtail lead, and connect the black supply lead 
to the heater black pigtail lead.  For 208 and 240 volt heaters change the 
color of the heaters white pigtail lead to black by wrapping with black elec-
trical tape.  (Most electrical codes require the supply leads to be con-
nected to black leads).  Then connect the two black supply leads to the 
two black receptacle leads.
2.
Secure supply ground wire under green ground screw in back box.
3.
Slide  supply  wiring  under  retaining  straps  in  back  box  to  hold  in
place.
4.
Insert wiring plug from heater/fan assembly into socket in back box.
5.
Fit heater/fan assembly into back box and secure in place with (2)
screws provided through the center slots in the fan assembly.
NOTE:  Use the screws provided by the factory to install fan deck to 
the back box.
GENERAL
The  heater  is  designed  for  recessed  installation  in  2”  X  4”  (50mm  X
101mm) stud or larger wall or ceiling sections using the wall box provid-
ed.    The  heater  may  also  be  surface  mounted  by  using  the  Surface
Mounting  Frame,  Model  SRASM  or  semi-recess  mounted  by  using  a
SRAS1 (for 1” (25 mm) recess frame) or a SRAS2 (for 2” (50mm) recess
frame).  All three accessories are ordered separately.  The heater may be
wired with standard building wire (60°C).  Refer to specification chart (see
pg. 4) for correct supply voltage and wire size.
NOTE: The optimum mounting height for this heater is 18" to 24" (450 to
600mm)  from  floor  to  bottom  of  back  box.    Do not install  closer  than
2”(50mm) from the floor. Back box may be mounted such that discharge
portion of grille can be oriented down, left, right, or up.  
For  surface  or  semi-recess  mounting,  consult    Installation  Instructions
packed with SRASM, SRAS1, SRAS2    
INSTALLATION OF WALL BOX
IN NEW CONSTRUCTION
(WALL OR CEILING)
NOTE:    If  the  finished  wall  surface  is  already  up,  follow  instructions  for
“INSTALLATION OF BACK BOX IN EXISTING CONSTRUCTION”.
1.
Determine which side of the back box is to be mounted against a
stud and bend the tabs at the rear corners out 90 degrees so that
the back box will be square with the stud after installation.  (See
Figure 1).  
2.
Remove  one  of  the  knockouts  on  socket  side  of  the  back  box  and
install a cable or conduit connector.
3.
Position back box  against side of studs and secure using nails or screws
as shown in Figure 1.
NOTE:  The back box must be installed with the front edge flush with the fin-
ished surface.
Figure 2
AN  ELECTRICAL SHOCK,  FIRE  OR  WATER  DAMAGE  COULD
RESULT IF  WIRING  OR  PIPING  IS  DAMAGED  DURING  CUTTING.
MAKE  SURE  ALL WIRING  AND  PIPING  ARE  CLEAR  OF  AREA
BEFORE CUTTING.
THE  HEATER  IS  HOT WHEN  IN  USE.    DO NOT INSTALL THE
HEATER  BEHIND  DOOR,  BEHIND  TOWEL RACK,  IN  CLOSET,
WHERE  CURTAINS  OR  DRAPES  COULD  TOUCH  OR  BECOME
SCORCHED  BY HEATER,  OR  WHERE AIRFLOW  TO  HEATER  MAY
BE OBSTRUCTED.   KEEP ELECTRICAL CORDS, BEDDING, FURNI-
TURE AND OTHER COMBUSTIBLES AWAY FROM HEATER.
FOR WALL MOUNTING,  DO NOT INSTALL HEATER CLOSER THAN
2" (51mm) TO THE FLOOR OR ANY ADJACENT WALL SURFACE.  DO
NOT  
INSTALL CLOSER  THAN  36"  (915mm)  TO  THE  CEILING.    FOR
CEILING  MOUNTING,  DO  NOT INSTALL CLOSER THAN  12”  (304mm)
TO ADJACENT WALL.
TO PREVENT HAZARD OF FIRE OR ELECTRICAL SHOCK, DO NOT
INSTALL WITHOUT BACK BOX.
CAUTION
IMPORTANT
WARNING
CAUTION
CAUTION
2
Figure 1
Remove red
jumper for
lower wattage
rating
!
!
!
!
!